On Fri, 7 Dec 2012, Sarah Sharp wrote:
> On Wed, Dec 05, 2012 at 12:14:07PM -0500, Alan Stern wrote:
> > On Tue, 4 Dec 2012, Sarah Sharp wrote:
> >
> > > An empty port can transition to either Inactive or Compliance Mode if a
> > > newly connected USB 3.0 device fails to link train. In that case
On Wed, Dec 05, 2012 at 12:14:07PM -0500, Alan Stern wrote:
> On Tue, 4 Dec 2012, Sarah Sharp wrote:
>
> > An empty port can transition to either Inactive or Compliance Mode if a
> > newly connected USB 3.0 device fails to link train. In that case, we
> > issue a warm reset. Some devices, such a
On Tue, 4 Dec 2012, Sarah Sharp wrote:
> An empty port can transition to either Inactive or Compliance Mode if a
> newly connected USB 3.0 device fails to link train. In that case, we
> issue a warm reset. Some devices, such as John's Roseweil eusb3
> enclosure, slip back into Compliance Mode af
An empty port can transition to either Inactive or Compliance Mode if a
newly connected USB 3.0 device fails to link train. In that case, we
issue a warm reset. Some devices, such as John's Roseweil eusb3
enclosure, slip back into Compliance Mode after the warm reset.
The current warm reset code