On Tue, 2018-07-31 at 01:35 -0400, Sreekanth Reddy wrote:
> In mpt3sas_base_clear_st() function smid value is reseted in wrong line,
> i.e. driver should reset smid value to zero after decrementing chain_offset
> counter in chain_lookup table but in current code, driver is resetting smid
> value be
On Thu, 2018-08-02 at 16:11 -0400, Martin K. Petersen wrote:
> > In mpt3sas_base_clear_st() function smid value is reseted in wrong
> > line, i.e. driver should reset smid value to zero after decrementing
> > chain_offset counter in chain_lookup table but in current code, driver
> > is resetting sm
Bart,
> In mpt3sas_base_clear_st() function smid value is reseted in wrong
> line, i.e. driver should reset smid value to zero after decrementing
> chain_offset counter in chain_lookup table but in current code, driver
> is resetting smid value before decrementing the chain_offset
> counter. whi
In mpt3sas_base_clear_st() function smid value is reseted in wrong line,
i.e. driver should reset smid value to zero after decrementing chain_offset
counter in chain_lookup table but in current code, driver is resetting smid
value before decrementing the chain_offset counter. which we are correctin