Hi Sakari,
Thank you for the patch.
On Wednesday 11 November 2015 01:34:18 Sakari Ailus wrote:
> The sequence number counter is incremented on each output buffer, and that
> incremented value is used as the sequence number of that buffer. The input
> buffer sequence numbering is based just on rea
The sequence number counter is incremented on each output buffer, and that
incremented value is used as the sequence number of that buffer. The input
buffer sequence numbering is based just on reading the same counter. If
the input buffer is marked done first, its sequence number ends up being
that