Re: [RFC PATCH] iio: adc: Add Xilinx AMS driver

2018-03-20 Thread Geert Uytterhoeven
On Sat, Mar 17, 2018 at 7:19 PM, Jonathan Cameron wrote: > On Sat, 17 Mar 2018 01:49:25 +0530 > Himanshu Jha wrote: > >> On Thu, Mar 15, 2018 at 08:12:27PM +0530, Manish Narani wrote: >> > The AMS includes an ADC as well as on-chip sensors that can be used to >> > sample external voltages and mon

Re: [RFC PATCH] iio: adc: Add Xilinx AMS driver

2018-03-17 Thread Jonathan Cameron
On Sat, 17 Mar 2018 01:49:25 +0530 Himanshu Jha wrote: > On Thu, Mar 15, 2018 at 08:12:27PM +0530, Manish Narani wrote: > > The AMS includes an ADC as well as on-chip sensors that can be used to > > sample external voltages and monitor on-die operating conditions, such as > > temperature and supp

Re: [RFC PATCH] iio: adc: Add Xilinx AMS driver

2018-03-17 Thread Jonathan Cameron
On Thu, 15 Mar 2018 16:51:31 +0100 (CET) Peter Meerwald-Stadler wrote: > minor comments below > > > The AMS includes an ADC as well as on-chip sensors that can be used to > > sample external voltages and monitor on-die operating conditions, such as > > temperature and supply voltage levels. The

Re: [RFC PATCH] iio: adc: Add Xilinx AMS driver

2018-03-16 Thread Himanshu Jha
On Thu, Mar 15, 2018 at 08:12:27PM +0530, Manish Narani wrote: > The AMS includes an ADC as well as on-chip sensors that can be used to > sample external voltages and monitor on-die operating conditions, such as > temperature and supply voltage levels. The AMS has two SYSMON blocks. > PL-SYSMON blo

Re: [RFC PATCH] iio: adc: Add Xilinx AMS driver

2018-03-15 Thread Peter Meerwald-Stadler
minor comments below > The AMS includes an ADC as well as on-chip sensors that can be used to > sample external voltages and monitor on-die operating conditions, such as > temperature and supply voltage levels. The AMS has two SYSMON blocks. > PL-SYSMON block is capable of monitoring off chip vol

[RFC PATCH] iio: adc: Add Xilinx AMS driver

2018-03-15 Thread Manish Narani
The AMS includes an ADC as well as on-chip sensors that can be used to sample external voltages and monitor on-die operating conditions, such as temperature and supply voltage levels. The AMS has two SYSMON blocks. PL-SYSMON block is capable of monitoring off chip voltage and temperature. PL-SYSMON