Re: [RESEND PATCH v5 0/4] add coupled regulators for Exynos5422/5800

2019-08-22 Thread Kamil Konieczny
Dear MyungJoo, On 08.08.2019 11:02, Kamil Konieczny wrote: > Hi, > > The main purpose of this patch series is to add coupled regulators for > Exynos5422/5800 to keep constrain on voltage difference between vdd_arm > and vdd_int to be at most 300mV. In exynos-bus instead of using > regulator_set

[RESEND PATCH v5 0/4] add coupled regulators for Exynos5422/5800

2019-08-08 Thread Kamil Konieczny
Hi, The main purpose of this patch series is to add coupled regulators for Exynos5422/5800 to keep constrain on voltage difference between vdd_arm and vdd_int to be at most 300mV. In exynos-bus instead of using regulator_set_voltage_tol() with default voltage tolerance it should be used regulator_

Re: [PATCH v5 0/4] add coupled regulators for Exynos5422/5800

2019-08-08 Thread Kamil Konieczny
Hi Chanwoo, On 08.08.2019 03:47, Chanwoo Choi wrote: > Hi Kamil, > > When I applied them to testing branch, those don't have the author name > only just have the email address as following: > You have to edit the your git author information with your name. Sorry, I will resend with proper From:

Re: [PATCH v5 0/4] add coupled regulators for Exynos5422/5800

2019-08-07 Thread Chanwoo Choi
Hi Kamil, When I applied them to testing branch, those don't have the author name only just have the email address as following: You have to edit the your git author information with your name. author k.koniec...@partner.samsung.com 2019-08-07 15:38:36 +0200 committer Chanwoo Choi

[PATCH v5 0/4] add coupled regulators for Exynos5422/5800

2019-08-07 Thread k . konieczny
Hi, The main purpose of this patch series is to add coupled regulators for Exynos5422/5800 to keep constrain on voltage difference between vdd_arm and vdd_int to be at most 300mV. In exynos-bus instead of using regulator_set_voltage_tol() with default voltage tolerance it should be used regulator_