Hi Neil,
On Wed, Nov 14, 2018 at 2:18 PM Neil Armstrong wrote:
>
> The Amlogic Meson GX SoCs embeds a clock measurer IP to measure the internal
> clock paths frequencies.
I would remove "GX" from that sentence
> The precision is determined by stepping into the divider until the counter
> overflo
The Amlogic Meson GX SoCs embeds a clock measurer IP to measure the internal
clock paths frequencies.
The precision is determined by stepping into the divider until the counter
overflows.
The debugfs slows a pretty summary and each clock can be measured
individually aswell.
The clock table covers
2 matches