Re: MAX 3 does not save SCXI chassis config under NIDAQ Traditional

2004-03-11 Thread lmd2
Yes Ni-DAQ 7.1 was the fix guess the original instal hicoughed or something much easier to upgrade NI DAQ than reinstall everything thanx for your help

MAX 3 does not save SCXI chassis config under NIDAQ Traditional

2004-03-10 Thread lmd2
I am upgrading an old system. I have Loaded LabVIEW 7, NI-DAQ 7.0.0f8, MAX 3.0.0.3014 Under NI-DAQ Tradional the PCI-E series daq card shows up and looks OK from the test screens. I right click on NI-DAQ Trad add an SCXI-1001 and configure the 9 SCXI modules (1120s, 1102, 1163Rs, 1160, and a breadb

Re: How to select NIDAQ traditional instead of NIDAQmx

2004-03-05 Thread lmd2
your answer #1 may very well be true, but I don't know the trick to make it happen, but answer #2 has me up and running, so thank you very much. lmd2

How to select NIDAQ traditional instead of NIDAQmx

2004-03-04 Thread lmd2
I am upgrading an old system, built in LabVIEW 4 back in 1997 (I am now running LV7): My 16E-4 daq card shows up under both NIDAQ traditional, and under NIDAQmx (with more info under mx) when I right click on "Devices and Interfaces" and add an SCXI-1001 it gets added to the mx I KNOW mx doesn't su