The PA-2A works I have used them and standard music speakers will work
though at lower output. Make sure what ever you use is water proof.
On Sun, 25 Aug 2002 18:42:29 -0500 "David Jeter"
<[EMAIL PROTECTED]> writes:
> Does anyone have experience with the Viking PA-2A? I have a customer
> that
>
It appears our TVS200 RS-232 port has died. The voicemail is working fine, otherwise.
I just can't get in to program new boxes.
Are there any known tricks or failure points that are fixable on-site, or is my only
choice to swap it out for a repair at Panasonic?
I did try setting the dial to 1
In a message dated 8/26/02 8:10:47 AM Eastern Daylight Time,
[EMAIL PROTECTED] writes:
> It appears our TVS200 RS-232 port has died. The voicemail is working fine,
> otherwise. I just can't get in to program new boxes.
>
> Are there any known tricks or failure points that are fixable on-sit
Does anyone have an idea if Cisco ATA 186 can interface to CO line side,
generating DTMF to the KXTA308 for DISA extension select?
I need to connect 2 pabxs through an ethernet connection. Any other
manufacturer? 3Com ?
Thanks in advance
Jorge
multipart/alternative
text/plain (text body --
I believe that by placing the red rotary switch in the "2" position will
ensure the default com parameters are set, 9600 N81. Move the switch and
power cycle the system and pray that the 232 port comes back up.
Mike Karaman
The Phone Network, Inc.
-Original Message-
From: [EMAIL PROTECT
Correction - Switch #1
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of
Michael Karaman
Sent: Monday, August 26, 2002 10:40 AM
To: [EMAIL PROTECTED]; [EMAIL PROTECTED]
Subject: RE: KX-T: TVS200 RS232 port dead
I believe that by placing the red rotary sw
https://b2b.panasonic.com you need your tech id and the default login info
from Panasonic
Thank You,
John Berry, Owner
Lantex Voice & Data Systems
6093 Horton Dr
La Mesa, Ca 91942
phone 619-690-4428
fax 619-741-6823
[EMAIL PROTECTED]
-Original Message-
From: Tim B. [mailto:[EMAIL PROTE
I just DL'd the new program & demo'd it on a -5 in my office. It seems
nice. It worked well with Win ME on my Toshiba laptop. I do use a USB to
Serial replicator to talk to serial devices.
Jim Marks
Denville Wiring Systems
Panasonic Phones & Voicemail
__
Hey guys,
Just had my first look at those 77 series and they
look pretty good to me. A customer on the mexican side
bought them chose those over the 73 i had offered him.
When will see those on the US side? i hope this year.
__
Do You Yahoo!?
Yahoo
We never had the courage to use Pano BRI cards, but
some basic info that might point to trouble shooting
isdn.
The call setup on isdn is all digital, on the D
channel, and there is no "dial-tone" etc. To provide
these "pacifier" tones, a BRI device with analog
("pots") ports will have "register(
Brian:
It is unlikely that the serial port is bad. The EIA RS-232 standard
requires that any pin can be connected to any pin for any length of
time with no damage. It is VERY likely that the RS-232 port has
somehow been configured in a strange way, or that the cable has
caused a short or open