Re: KX-T: RF & ac noise

2007-07-23 Thread Jim Schultz
erial and duct cable with a foil sheath isn't it? Good luck! Jim - Original Message - From: "Donald R. Resor" <[EMAIL PROTECTED]> To: "KXT help List" Sent: Monday, July 23, 2007 4:14 PM Subject: Re: KX-T: RF & ac noise > This may be a dumb questio

Re: KX-T: RF & ac noise

2007-07-23 Thread David Lesher
Speaking on Deep Background, the Press Secretary whispered: > > I have a digital pbx I look after (ComDial) That has about 1000' aerial 25 > pair cable between buildings. Each end has a gas tube protection and > additional analog & digital protection. The problem is RF and ac noise. I > p

Re: KX-T: RF & ac noise

2007-07-23 Thread Donald R. Resor
This may be a dumb question, but is the 1000 feet of 25 pair run inside a steel conduit? At 01:02 PM 7/23/2007, you wrote: >I have a digital pbx I look after (ComDial) That has about 1000' aerial 25 >pair cable between buildings. Each end has a gas tube protection and >additional analog & digita

Re: KX-T: RF & ac noise

2007-07-23 Thread Donald R. Resor
This may be a dumb question, but is the 1000 feet of 25 pair run inside a steel conduit? At 01:02 PM 7/23/2007, you wrote: >I have a digital pbx I look after (ComDial) That has about 1000' aerial 25 >pair cable between buildings. Each end has a gas tube protection and >additional analog & digita

KX-T: RF & ac noise

2007-07-23 Thread DIALTONE1
I have a digital pbx I look after (ComDial) That has about 1000' aerial 25 pair cable between buildings. Each end has a gas tube protection and additional analog & digital protection. The problem is RF and ac noise. I put am & fm chocks on, grounded spare pairs @ each end, and am still g