On Mon, Nov 03, 2014 at 01:15:24PM +0100, Daniel Vetter wrote:
> On Tue, Oct 28, 2014 at 04:30:41PM +0200, Ville Syrjälä wrote:
> > On Tue, Oct 28, 2014 at 11:26:51AM -0200, Paulo Zanoni wrote:
> > > >> + /*
> > > >> + * We can't change the DDI type if we already have a
>
On Tue, Oct 28, 2014 at 04:30:41PM +0200, Ville Syrjälä wrote:
> On Tue, Oct 28, 2014 at 11:26:51AM -0200, Paulo Zanoni wrote:
> > >> + /*
> > >> + * We can't change the DDI type if we already have a
> > >> connected
> > >> + * device on this port. The first t
On Tue, Oct 28, 2014 at 11:26:51AM -0200, Paulo Zanoni wrote:
> 2014-10-28 5:49 GMT-02:00 Daniel Vetter :
> > On Mon, Oct 27, 2014 at 05:47:51PM -0200, Paulo Zanoni wrote:
> >> From: Paulo Zanoni
> >>
> >> On HSW+, one encoder (DDI) can have multiple connectors (HDMI and DP).
> >> If no connector
2014-10-28 5:49 GMT-02:00 Daniel Vetter :
> On Mon, Oct 27, 2014 at 05:47:51PM -0200, Paulo Zanoni wrote:
>> From: Paulo Zanoni
>>
>> On HSW+, one encoder (DDI) can have multiple connectors (HDMI and DP).
>> If no connector is connected, we consider the encoder type to be
>> INTEL_OUTPUT_UNKNOWN.
On Tue, Oct 28, 2014 at 08:46:21AM -0200, Paulo Zanoni wrote:
> 2014-10-28 5:49 GMT-02:00 Daniel Vetter :
> > On Mon, Oct 27, 2014 at 05:47:51PM -0200, Paulo Zanoni wrote:
> >> From: Paulo Zanoni
> >>
> >> On HSW+, one encoder (DDI) can have multiple connectors (HDMI and DP).
> >> If no connector
2014-10-28 5:49 GMT-02:00 Daniel Vetter :
> On Mon, Oct 27, 2014 at 05:47:51PM -0200, Paulo Zanoni wrote:
>> From: Paulo Zanoni
>>
>> On HSW+, one encoder (DDI) can have multiple connectors (HDMI and DP).
>> If no connector is connected, we consider the encoder type to be
>> INTEL_OUTPUT_UNKNOWN.
On Mon, Oct 27, 2014 at 05:47:51PM -0200, Paulo Zanoni wrote:
> From: Paulo Zanoni
>
> On HSW+, one encoder (DDI) can have multiple connectors (HDMI and DP).
> If no connector is connected, we consider the encoder type to be
> INTEL_OUTPUT_UNKNOWN. The problem is that we allow user space to set
>
From: Paulo Zanoni
On HSW+, one encoder (DDI) can have multiple connectors (HDMI and DP).
If no connector is connected, we consider the encoder type to be
INTEL_OUTPUT_UNKNOWN. The problem is that we allow user space to set
modes on disconnected connectors, so when we try to set a mode on an
INTE