On Tuesday 26 of March 2013 16:49:30 Daniel Vetter wrote:
> On Tue, Mar 26, 2013 at 4:40 PM, Michal Srb wrote:
> > I have IBM POS machine (4852-570 Truman) that has internal monitor
> > connected over display port. It reports to have 2 lanes, but only 1
> > lane works reliab
Since 2514bc510d0c3aadcc5204056bb440fa36845147, the intel_dp_mode_fixup
function prefers lane count over frequency. That causes problems on
hardware that has less working lanes than it reports. This option allows
to workaround such hardware bugs.
Signed-off-by: Michal Srb
---
This is workaround
doesn't look like correct way
to fix this...
Thank you,
Michal Srb
___
Intel-gfx mailing list
Intel-gfx@lists.freedesktop.org
http://lists.freedesktop.org/mailman/listinfo/intel-gfx