What you need to do is order a MES to extend the current CBU record, not create
a new one. As long as the current CBU term has not expired, it can be extended
and the installation of this is non-disruptive. Talk to your BP z tech or IBM z
tech and they can explain this in more detail.
-
You should only need to add a new VIPA:
For all traffic that is initiated to your system, they just specify the
destination IP address 7.7.7.8, or create a DNS entry that resolves to that
address and have them use that host name.
For most of traffic the that you initiate outbound I would look
John,
Thanks for your time and the thorough response. I’m not too concerned about the
applications, but your comments confirmed what I thought in that area.
One quick test failed to work in the OSPF space (did not recognize the new IP
address). However, I think I’ll have another test opportunity
O.K., that is a routing issue. You need to look at your OSPF parameters and
verify that you are setup to advertise 7.7.7.8 to your neighbors. If your
not, then you need to update you OSPF parameters to advertise it and go from
there. No matter what you may want to check with whomever handles
Hello Jim
Under HMC - Perform model conversion
I don't see extension options
On Mon, 12 Aug 2024, 14:52 Jim Elliott, <
060a87997a77-dmarc-requ...@listserv.ua.edu> wrote:
> What you need to do is order a MES to extend the current CBU record, not
> create a new one. As long as the current CBU
Thanks again.
I understand it’s a routing issue and I added a matching OSPF_Interface where
the original one was defined, using the new IP and Destination Address.
But when I issue the OBEYFILE command I get “EZZ7871I NO MATCHING INTERFACE
STATEMENTS FOR 7.7.7.8 (VIPALINK2)”.
My gut instinct keep
https://www.google.com/url?sa=t&source=web&rct=j&opi=89978449&url=https://www.ibm.com/support/pages/sites/default/files/inline-files/SC28-6846-02c.pdf&ved=2ahUKEwios-OKzu-HAxV2U0EAHSGuIzUQFnoECEAQAQ&usg=AOvVaw35iaouKAIpO7mNt4jiwcD2
https://www.google.com/url?sa=t&source=web&rct=j&opi=89978449&url
HI
I use only one static Vipa / lpar
but we have some dynamic VIPAS for each application (FTP, CICS, DB2 and
so on..)
it works fine.
regards
Wolfgang
Am 12.08.2024 um 15:51 schrieb roscoe5:
Thanks again.
I understand it’s a routing issue and I added a matching OSPF_Interface where
the
For a given ASID, look at OUCB +B0. JES2, STC or TSO should appear.
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Seymour J Metz
Sent: Thursday, August 8, 2024 9:20 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: Couple of questions about job id
CAUTION! T
My main problem was, I tried to use an OBEYFILE command to refresh OMPROUTE. I
believe I should be using a MODIFY. F OMPROUTE,RECONFIG
I’m not yet 100% there, but past my original questions.
Thanks for your help
Sent from [Proton Mail](https://proton.me/mail/home) for iOS
On Mon, Aug 12, 2024 a
Hi all,
I'll share a number of thoughts on this thread, in no particular order
> I have found this thread interesting, and what I believe is needed
> is a SSI ROLLBACK or UNDO function. So that in the ESTAE/ESTAEX routine
> or in the init routine itself the "system" would remove any changes m
> > Change the subsystem name in the SSCT (perhaps change one character to lower
> > case) and free everything. Of course, be careful that nothing is running in
> > the code dynamically loaded.
Isn't it possible that the subsystem name occurs elsewhere and/or has been
in some way added to a hashed
List
I have a condition where if I do TSO NETSTAT (PORT 23 - Yep Mainframe
I am seeing lots of IP Addresses in STATE LASTACK
This cause me to do a lot of TCPIP DROP commands to clear it out
I have had to build Several Automation functions to drop them hourly. I
have had
Global Mirror (GM) system - Global Mirror Failover/Failback w/Practice.
Trying to increase the PPRC paths in GM, looking for inputs if anyone in this
group have performed this through IBM CSM.
I have validated additional new paths already and ready to configure.
Here is the plan:
Step 1: Pause
Just an FYI - lesson learned if anyone cares. I had planned to dynamically add
the new interface in both the PROFILE dataset and in OMPROUTE.
It turns out the order is very important, and I Assumed wrong.
I did the Obey on the Profile first, which caused OSPF to learn partial info.
It dynamically
10,* is your Wide Area Network within your business router. Similar
to 192,168.* within a smaller router
https://en.wikipedia.org/wiki/Private_network
On Mon, Aug 12, 2024 at 12:50 PM Lizette Koehler
wrote:
>
>
>
> List
>
>
>
> I have a condition where if I do TSO NETSTAT (PORT 23 - Yep Mai
Client power off will do that ... are these virtual machine clients? Those
are easy to power off thoughtlessly. The state isn't really a problem, the
session is closed but client hasn't sent the last ACK. Everything is
cleaned up in z/OS except whatever control block Netstat is using to show
tha
17 matches
Mail list logo