Gentlemen,
Let me explain again.
It wasn't a joke, I had really read about 12-inch floppies. It was a
book, not just someone's junk post to some forum.
The book is dated 2006
Title: Introduction to Computers
Editor: Rajmohan Joshi
ISBN: 81-8205-379-X
page 79
In fact I did not believe the info
I just started z/OS 3.1 installation using z/OSMF.
So far, so good.
I am on "Configure this deployment - Data Sets" stage.
I noticed all my datasets have a name like CB.ST123456.SYS1.LINKLIB.
ST123456 is an order number.
Obviously I wan to have SYS1.LINKLIB, without two first qualifiers
CB.ST
I still have some 8" IBM floppy disks on my shelf. One even auto-plays a
golf game if inserted into a 3741/3742.
While the original question was on 12" disks, the information provided
in the replies about 8" disks has been 'very poor'.
The university where I got my training used first 80 colu
Hi,
I have tried adding extra cylinders for PDS dataset which is in use.
I have tried it using the tool PDS86 but the extend was failed with SE37,
even though we have enough space on the volume.
Now, I am getting a "Severe Error" While opening a Dataset in ISPF 3.4. Any
Help on this?
Regards,
R
For BYADDR=NO the entry point is being updated but not the length it
returns a constant not reflective of the true module length consequently for
a number of modules only part of it is being copied to LPA
Nonsense. Prove it.
CSVDYLPA never returns a "constant" for module length. If it returned a
Thank you for mentioning author and title.
I found this short bio:
Raj Mohan Joshi, a renowned lecturer of biotechnology, has had a brilliant
academic record. He has worked with various institutes and has participated in
many national and international conferences. He is widely travelled. He has
PDS is limited to 1 volume 16 extents, PDSE limited to 1 volume 12? extents.
https://www.techagilist.com/mainframe/jcl/space-abend-sb37-sd37-se37-resolution/
says SE37 says no more volumes are available.
So, either you have 16 extents, or the secondary allocation is larger
than the largest free spa
Hi Radoslaw.
Yes, you have to rename most of the datasets but it is not as bad as it sounds.
I think I mapped the datasets to.target volumes and then filtered on the volume
to get a list of all sysres datasets. Then you can change the CB.
ST123456 prefix to null for all of those datasets in one
Radoslaw Skorupka wrote, in part:
>BTW: Privately I am floppy disk entomologist.
So...you deBUG floppies? /s
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the messa