Does this program use z/OS Unix services to spawn child processes to handle
modify commands?
There can be issues with IEE342I being issued when base jobname is 8 chars long
and a different jobname cannot be formed by appending an extra character.
Rob Scott
Rocket Software
Sent from Samsung M
No z/OS Unix Services used.
Good ol' fashioned MVS assembler program.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Q1 : Is the jobname unique on the system?
Q2 : What happens when you start the address space using "S PROCNAME.MYID" and
then issue "F MYID,command" ?
Rob Scott
Rocket Software
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Support, DUNNIT SYSTEMS LTD.
Sent: Wedne
Hi Rob,
Q1 : Is the jobname unique on the system?
A1 : Yes. BTW, STC, not JOB.
Q2 : What happens when you start the address space using "S PROCNAME.MYID" and
then issue "F MYID,command" ?
A2 : with MYID, all's normal - no message IEE342I issued. Shut it down,
restarted without ID and the prob
Here is what I suspect is happening - note that I don't have access to the z/OS
BCP code - so some of this is semi-educated guess :
(o) CONSOLE operator command processing is fairly simple and its main purpose
here is to add a CIB to the appropriate queue for the responding address space
(o) IE
Rob,
WOW!
>> When the modify command comes in, the CSCB chain is run and ANY match on the
>> PROCNAME or ID (CHPROCSN and CHKEY for STC) triggers the logic to attempt to
>> add the CIB to that address space queue
PROC has same name as an active TSO user. When I rename the PROC, the problem
is
Great analysis.
Just tried F,INIT,XYZ and I got 10 messages. Guess how many INITs I am running?
Lennie
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of Rob
Scott
Sent: 18 October 2023 11:41
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: IEE342I MODIFY REJECTED-TASK BUSY -
Yeh. I was waiting for someone else to give it a try.
>> From: Lennie Dymoke-Bradshaw
>>
>> Great analysis.
>> Just tried F,INIT,XYZ and I got 10 messages. Guess how many INITs I am
>> running?
--
For IBM-MAIN subscribe / signo
On Fri, 13 Oct 2023 21:17:14 +, Seymour J Metz wrote:
>On other browsers target=_blank opens a new tab, and I saw a message to the
>effect that there is no way around it. On my personal machines I can just use
>Chrome or Firefox, but my work laptop is locked down and I can only use
>approve
I'll try to explain this as best as I can, but this can get confusing and this
is based on my understanding. We do have DB2 setup in Data Sharing and
configured using SYSPLEX distributor, which some of the configuration is
similar.
When TCPIP on z/OS allocates a IP address that address is
It turns out that the setting is locked to download. Given that, I'll look at
constructing shortcuts. Can windows shortcuts use relative paths?
I wish that IBM would include not only the exact title in PDF metadata but also
the forms code.
--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~sme
Classification: Confidential
Agreed, however it seems the OP is operating in a "toggle-plex" i.e. either
LPAR A is running or LPARB is running. In this case, the DVIPA would be
deactivated on one of the LPARS and switched manually via the V TCPIP command
to activate/deactivate the DVIPA on LPAR
On Wed, 18 Oct 2023 16:53:48 +, Seymour J Metz wrote:
>...I wish that IBM would include not only the exact title in PDF metadata but
>also the forms code.
>
Are the metadata extensible? In one 3.1 publication I see:
Custom Metadata: no
But suppose the document is rendered before a forms
On 10/18/2023 9:53 AM, Seymour J Metz wrote:
Can windows shortcuts use relative paths?
Maybe, but it doesn't work for me on Win 10:
Currently my VBS script creates links like this depending on what
directory you are in when you run the script (pwd):
https://www.mildredbrennan.com/mvs/shortc
Tom,
For the “relative” idea, maybe fill in the “Start In” value in the *.lnk file
with the “current” (pwd) directory name? Not sure if that would make any
difference, but it may be worth a try.
Peter
From: IBM Mainframe Discussion List On Behalf Of Tom
Brennan
Sent: Wednesday, October 18,
Everyone that I've seen has a forms code on the front cover.
--
Shmuel (Seymour J.) Metz
http://mason.gmu.edu/~smetz3
עַם יִשְׂרָאֵל חַי
From: IBM Mainframe Discussion List on behalf of
Paul Gilmartin <042bfe9c879d-dmarc-requ...@listserv.ua.e
On Wed, 18 Oct 2023 18:15:55 +, Farley, Peter wrote:
>Tom,
>
>For the “relative” idea, maybe fill in the “Start In” value in the *.lnk file
>with the “current” (pwd) directory name? Not sure if that would make any
>difference, but it may be worth a try.
>
Are you using Tom's shortcuts or Tm
Hello All,
Thanks in advance for anyone that can shed light on the subject.
Is there a mechanism for setting a JCL type variable from within a program?
In other words, I would like to do this:
// SET XYZ='ABC and DEF'
from within a program.
Again, thanks for anyone that can shed light on this
On Wed, 18 Oct 2023 16:18:05 -0500, Charles Hardee wrote:
>
>Thanks in advance for anyone that can shed light on the subject.
>
>Is there a mechanism for setting a JCL type variable from within a program?
>
I hope you can't.
JCL symbols are elaborated by the Converter, before a program executes.
Why would you want/need to do this?
Michael
At 04:18 PM 10/18/2023, Charles Hardee wrote:
Hello All,
Thanks in advance for anyone that can shed light on the subject.
Is there a mechanism for setting a JCL type variable from within a program?
In other words, I would like to do this:
// SET
On Wed, Oct 18, 2023 at 16:28 Paul Gilmartin <
042bfe9c879d-dmarc-requ...@listserv.ua.edu> wrote:
> On Wed, 18 Oct 2023 16:18: 05 -0500, Charles Hardee wrote:
> >
> >Thanks in advance for anyone that can shed light on the subject.
> >
> >Is there a umechanism for setting a JCL type variable fr
On the other hand they can be passed to another job via the internal reader
specified with the SYMBOLS parameter.
For example,
//INTRDR DD *,SYMLIST=*
It could make sense in this instance.
Lennie Dymoke-Bradshaw
https://rsclweb.com
‘Dance like no one is watching. Encrypt like everyone is.’
-
On Wed, 18 Oct 2023 22:53:05 +0100, Lennie Dymoke-Bradshaw wrote:
>On the other hand they can be passed to another job via the internal reader
>specified with the SYMBOLS parameter.
>For example,
>//INTRDR DD *,SYMLIST=*
>It could make sense in this instance.
>
ITYM:
// EXPORT SYMLIST=
On Wed, 18 Oct 2023 16:18:05 -0500, Charles Hardee
wrote:
>Is there a mechanism for setting a JCL type variable from within a program?
>
>In other words, I would like to do this:
>
>// SET XYZ='ABC and DEF'
>
>from within a program.
You're asking for a solution to a problem that we don't unders
Write a program that outputs a JOB with the desired JCL and variables.
Some automation programs can modify JCL in a library when it submits
it.
On Wed, Oct 18, 2023 at 4:19 PM Charles Hardee wrote:
>
> Hello All,
>
> Thanks in advance for anyone that can shed light on the subject.
>
> Is there a
On Wed, 18 Oct 2023 11:02:15 -0700, Tom Brennan
wrote:
>On 10/18/2023 9:53 AM, Seymour J Metz wrote:
>> Can windows shortcuts use relative paths?
>
>Maybe, but it doesn't work for me on Win 10:
Symlinks (hard or soft) is an alternative to using shortcuts.
Environment variables are allowed in
In my tests, symlinks (mklink command) needs admin auth to create. That
would scare people I think.
I'm not interested in messing with somebody's environment variables.
That would scare people too I think.
Yes there's a reason not to rename: The manuals have internal links to
each other wh
On Wed, 18 Oct 2023 18:31:11 -0500, Mike Schwab wrote:
>Write a program that outputs a JOB with the desired JCL and variables.
>Some automation programs can modify JCL in a library when it submits
>it.
There are many problems with this solution because we are making assumptions
about the proble
On Wed, 18 Oct 2023 11:50:21 -0500, John S. Giltner, Jr.
wrote:
>When TCPIP on z/OS allocates a IP address that address is registered in the
>OSA
> so that the OSA has a list of every IP address that is open and which LPAR it
> is opened on.
This tells us that in addition to SNA, the OSA i
Point taken about the problems. If you don't want the CMD screen popping up,
then change the shortcut to run minimized.
Have you thought about generating a word document with hyperlinks to each of
the manuals without path. Save the word document as a PDF in the same directory
as the manuals.
O
On Wed, 18 Oct 2023 17:18:33 +, Allan Staller wrote:
>Agreed, however it seems the OP is operating in a "toggle-plex" i.e. either
>LPAR A is running or LPARB is running. In this case, the DVIPA would be
>deactivated on one of the LPARS and switched manually via the V TCPIP command
>to acti
No thanks, I'll just stick with what I have since it works already.
On 10/18/2023 8:27 PM, Jon Perryman wrote:
Point taken about the problems. If you don't want the CMD screen popping up,
then change the shortcut to run minimized.
Have you thought about generating a word document with hyperlin
Possibly what they want to do is be able to create or change the symbolic after
the job has started. Isn't there a program interface to generating symbols?
Brian
--
For IBM-MAIN subscribe / signoff / archive access instructions
In fact, it works VERY well. I don't mind the dos boxes opening and closing,
they are REALLY fast and if there wern't so many of them you probably would not
notice that anything happened.
--
For IBM-MAIN subscribe / signoff / a
34 matches