Re: SMPe Apply not working

2020-06-12 Thread Jesse 1 Robinson
obile 626-543-6132 Office ⇐=== NEW robin...@sce.com -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bill Giannelli Sent: Friday, June 12, 2020 4:09 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: (External):Re: SMPe Apply not working CAUTION EXTERNAL EMAIL I really appreciate everyon

Re: SMPe Apply not working

2020-06-12 Thread Bill Giannelli
I really appreciate everyone's help here! The issue I had I believe was that I failed to specify FORFMID. However, I need to take a step back and review my SMPe environment. The CSI was handed off to me and I am finding some things wrong, like missing FMIDs for some of my base products. thank you

Re: SMPe Apply not working

2020-06-11 Thread Gibney, Dave
This list doesn't do attachments. > -Original Message- > From: IBM Mainframe Discussion List On > Behalf Of Bill Giannelli > Sent: Thursday, June 11, 2020 11:36 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: SMPe Apply not working > > I attached the appl

Re: SMPe Apply not working

2020-06-11 Thread Carmen Vitullo
- Original Message - From: "Bill Giannelli" To: IBM-MAIN@LISTSERV.UA.EDU Sent: Thursday, June 11, 2020 1:29:26 PM Subject: Re: SMPe Apply not working APPLY PTFS BYPASS( HOLDSYSTEM(ACTION,AO,DB2BIND,DEP,DOC,IPL,MULTSYS)) GROUPEX

Re: SMPe Apply not working

2020-06-11 Thread Bill Giannelli
I attached the apply check and the nonapply list -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: SMPe Apply not working

2020-06-11 Thread Bill Giannelli
APPLY PTFS BYPASS( HOLDSYSTEM(ACTION,AO,DB2BIND,DEP,DOC,IPL,MULTSYS)) GROUPEXTEND CHECK . -- For IBM-MAIN subscribe / signoff / archive access

Re: SMPe Apply not working

2020-06-11 Thread Allan Staller
Wrong Global zone specified? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bill Giannelli Sent: Thursday, June 11, 2020 12:18 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: SMPe Apply not working [CAUTION: This Email is from outside the Organization. Unless you trust

Re: SMPe Apply not working

2020-06-11 Thread Lizette Koehler
. CONTINUES. Liette -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bill Giannelli Sent: Thursday, June 11, 2020 10:27 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: SMPe Apply not working GIM59603IENQ WAS SUCCESSFUL FOR SHARED USE OF OEMPP.DB2.V12R02M0.SMPPTS1 FOR

Re: SMPe Apply not working

2020-06-11 Thread Carmen Vitullo
.EDU Sent: Thursday, June 11, 2020 12:59:06 PM Subject: Re: SMPe Apply not working And the output from smpout and smprpt > -Original Message- > From: IBM Mainframe Discussion List On > Behalf Of Binyamin Dissen > Sent: Thursday, June 11, 2020 10:57 AM > To: IBM-MAIN@L

Re: SMPe Apply not working

2020-06-11 Thread Gibney, Dave
And the output from smpout and smprpt > -Original Message- > From: IBM Mainframe Discussion List On > Behalf Of Binyamin Dissen > Sent: Thursday, June 11, 2020 10:57 AM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: SMPe Apply not working > > Show the APPLY statem

Re: SMPe Apply not working

2020-06-11 Thread Binyamin Dissen
Show the APPLY statement. On Thu, 11 Jun 2020 12:27:00 -0500 Bill Giannelli wrote: :>GIM59603IENQ WAS SUCCESSFUL FOR SHARED USE OF OEMPP.DB2.V12R02M0.SMPPTS1 FOR :>GIM59603IENQ WAS SUCCESSFUL FOR SHARED USE OF OEMPP.DB2.V12R02M0.SMPPTS2 FOR :>GIM24801S ** NO SYSMODS SATISFIED THE OPERA

Re: SMPe Apply not working

2020-06-11 Thread David Spiegel
Maybe the Zone is set to an incorrect Zone. (i.e SET BDY(TZONE).) On 2020-06-11 13:17, Bill Giannelli wrote: I ran a GIMSUP download, unpack, receive which ran clean. I see the received ptfs in a LIST NOAPPLY. But when I run theAPPLY I get "NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE AP

Re: SMPe Apply not working

2020-06-11 Thread Bill Giannelli
GIM59603IENQ WAS SUCCESSFUL FOR SHARED USE OF OEMPP.DB2.V12R02M0.SMPPTS1 FOR GIM59603IENQ WAS SUCCESSFUL FOR SHARED USE OF OEMPP.DB2.V12R02M0.SMPPTS2 FOR GIM24801S ** NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY COMMAND. GIM59606IDEQ WAS SUCCESSFUL FOR EXCLUSIVE USE OF OEM

Re: SMPe Apply not working

2020-06-11 Thread Lizette Koehler
Sent: Thursday, June 11, 2020 10:18 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: SMPe Apply not working I ran a GIMSUP download, unpack, receive which ran clean. I see the received ptfs in a LIST NOAPPLY. But when I run theAPPLY I get "NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY&q

SMPe Apply not working

2020-06-11 Thread Bill Giannelli
I ran a GIMSUP download, unpack, receive which ran clean. I see the received ptfs in a LIST NOAPPLY. But when I run theAPPLY I get "NO SYSMODS SATISFIED THE OPERANDS SPECIFIED ON THE APPLY". What could I be doing wrong? thanks Bill