Is it an option to use a h/w service provider such as BlueChip (UK-based)... or
any org in your location that would do a one-off?
- KB
--- Original Message ---
On Tuesday, April 11th, 2023 at 8:59 PM, Tom Longfellow
<03e29b607131-dmarc-requ...@listserv.ua.edu> wrote:
> Yes, I agr
f Tom
Longfellow <03e29b607131-dmarc-requ...@listserv.ua.edu>
Sent: Tuesday, April 11, 2023 11:29 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: TS7700 abandoned volumes questions
Yes, I agree that the only safe way out is to leave it to the professionals
that created the problem.The first h
So, for a shop about to decommission a system or storage device, we should
scratch all real data volumes,
create a volume full of junk data and
Repeatedly copy junk data from volume to volume
until it runs out of space
then expire the junk?
I did this with ICKDSF TRKFMT to erase dasd volumes..
On
Yes, I agree that the only safe way out is to leave it to the professionals
that created the problem.The first hurdle would be having a relationship
with them that allows me to make requests or demands.Unless it is a broken
situation that I can report to support as a 'problem' I have no
I agree. If you have the option of going to the source, that would probably be
the safest approach.
From: IBM Mainframe Discussion List on behalf of
Pommier, Rex
Sent: Monday, April 10, 2023 4:48 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: TS7700
oach would be to go to the source (i.e. IBM) and
get their approach for cleaning this up.
My $.01.
Rex
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Enzo D'Amato
Sent: Monday, April 10, 2023 3:04 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: T
$.01.
Rex
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Enzo D'Amato
Sent: Monday, April 10, 2023 3:04 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: TS7700 abandoned volumes questions
I don't think this is the "IBM-approved" way of
I don't think this is the "IBM-approved" way of doing things, but the ts7700s
use standard FC drive shelves. Have you tried breaking the cluster links,
powering down the controller, and then manually mounting the FC shelves on a
generic Linux box? If you can do that, you should be able to search
I'm afraid the best bet is to work with IBM VTL engineers to manually get rid
of them.
- KB
--- Original Message ---
On Monday, April 10th, 2023 at 7:15 AM, Mark Jacobs
<0224d287a4b1-dmarc-requ...@listserv.ua.edu> wrote:
> I'm not able to answer your question but I totally sympath
I'm not able to answer your question but I totally sympathize. There have been
many times where I wanted "systems programmer mode" to be enabled where the
@#$!!**@#$ software would let me do what I asked, regardless of whether it
thought it was smarter than I am and wouldn't do what I asked for.
ERV.UA.EDU
> Subject: Re: TS7700 physical tape drive failed
>
> Now it's resolved by IBM hardware engineer.
>
> The 3592 tape drive went offline after a firmware update and had to
> restart
> the VTL.
>
> Any clue to set an email alert when drives goes offline ?
&
Timed automation to display status of libraries (once per hour?).
Message automation to react to offline status.
On Sun, May 5, 2019 at 3:24 PM Jake Anderson wrote:
>
> Now it's resolved by IBM hardware engineer.
>
> The 3592 tape drive went offline after a firmware update and had to restart
> th
Now it's resolved by IBM hardware engineer.
The 3592 tape drive went offline after a firmware update and had to restart
the VTL.
Any clue to set an email alert when drives goes offline ?
On Sun, 5 May, 2019, 8:39 AM Mike Schwab, wrote:
> http://www.redbooks.ibm.com/redbooks/pdfs/sg248366.pdf
>
http://www.redbooks.ibm.com/redbooks/pdfs/sg248366.pdf
TS7700 V Updated 2019. Chapter 10. This is a list of the mainframe
z/os console commands to operate the library, assuming properly
configured and data replicated.
DISPLAY SMS,LIBRARY(ALL),DETAIL or D SMS,LIB(ALL),DETAIL lists the
libraries
Hi
Just to add
I was looking through the TS7700 events and found a fix procedure as
HYDIN0671I
All drives are reported are in the busy state
All the drives are reported as errno=5
Which translates to physical library is offline to host
Jake
On Sun, 5 May, 2019, 8:05 AM Jake Anderson,
wrote:
Hi
It's not that clear, but for FICON ports on each of my VTS arrays, the GUI
shows:
Slot 3, Ficon Card 2, Port 0
Slot 6, Ficon Card 3, Port 0
Slot 3, Ficon Card 0, Port 0
Slot 6, Ficon Card 1, Port 0
I think card 1 and 2 are 'Alternate' and card 0 and 3 are 'Primary'. The
engineer should be a
Under the Virtual Volume tab, you can display Incoming Copy Queue.
Brian
On Tue, 27 Nov. 2018, 16:07 Jake Anderson, wrote:
> Hi All,
>
> I am going through the ts7700 logon interface but I don't see any tab or
> place which says about the status of TS7700 replication.
>
> The replication is happ
There's various redbooks/manuals which explain the replication in the TS7700
Grid however it's based on the policy you setup and the SMS Routines setup...
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send em
nt
class. It comes with a GUI that makes it easy to define the policy.
Cheers,
Simon.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Peter
Sent: 02 September 2018 12:14
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: [EXTERNAL] Re: Ts7700 re
gt; Sent: 02 September, 2018 13:28
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Re: Ts7700 replication
>
> As far as I know, the policy Is defined within the TS7760.
>
> -Original Message-
> From: IBM Mainframe Discussion List On Behalf
> Of Peter
> Sent: Sunday, S
On Sun, 2 Sep 2018 14:09:43 +0400, Peter wrote:
>Hi
>
>I confess that I have no knowledge about ts7700. Wanted to know how ts7700
>tape gets copied to the disaster site ?
>
>Can someone please explain me ?
>
>Peter
>
Peter,
As I posted to another query, I would suggest you get a hold o
As far as I know, the policy Is defined within the TS7760.
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Peter
Sent: Sunday, September 2, 2018 2:14 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Ts7700 replication
Is the policy written on Mainframe or is it within
Is the policy written on Mainframe or is it within TCPIP on when it needs
to be copied ?
On Sun 2 Sep, 2018, 2:52 PM Gadi Ben-Avi, wrote:
> I have very limited knowledge but:
> When two, or more, TS7700's are connected it is called a grid
> configuration.
> The different members of a grid are co
I have very limited knowledge but:
When two, or more, TS7700's are connected it is called a grid configuration.
The different members of a grid are connected using an IP network.
There is a policy that defines when a tape is copied.
You can copy a tape when it is closed, or at the end of every bloc
TS7700 can replicated data using so called grid, that means two TS7700 boxes
replicate data using gigabit ethernet (TCPIP) connection.
HTH
--
Radoslaw Skorupka
--
For IBM-MAIN subscribe / signoff / archive access instructions,
ssion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of retired mainframer
Sent: Friday, April 06, 2018 11:33 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: TS7700 Copy/Export Jobs
Unless something has changed in the last five years, this job will simply copy
the three input records in SYSUT1 to th
Unless something has changed in the last five years, this job will simply
copy the three input records in SYSUT1 to the new dataset specified by
SYSTU2. The command EXPORT does not appear anywhere in the IEBGENER chapter
of my utilities manual.
> -Original Message-
> From: IBM Mainframe D
This document goes on to mention a sequence of steps, those to occur after
creating the tape-volume, of course with the various correct/expected
attributesone being "Initiating the Copy Export Operation" via a z/OS
command.
http://www-01.ibm.com/support/docview.wss?uid=tss1wp101092&aid=1
S
anything about TS77xx is always h/w related - a PMH via your friendly IBM CE
will be the way.
"software support" -- DFSMS, OAM -- will be via PMR
- ravi.
On Sun, 17 Aug 2014 22:27:14 -0500, Ravi Gaur wrote:
>Could anybody direct me for opening TS7700 IBM SOFTWARE PMR which product we
>nee
Are you asking about the software that runs the TS7720?
Or are you talking about software like RMM?
In the first case, a hardware PMR is probably the right group. However, have
you contacted your SE for assistance?
Lizette
> -Original Message-
> From: IBM Mainframe Discussion List [
@LISTSERV.UA.EDU
Subject: Re: TS7700 - Allocation Control to a Single Cluster within a Grid
The management class definition within the management interface allows you to
select scratch mount candidates as well as selecting which clusters will hold
the logical volume once it has been closed.
The 2
The management class definition within the management interface allows you
to select scratch mount candidates as well as selecting which clusters will
hold the logical volume once it has been closed.
The 2 options don't necessarily have to point to the same clusters.
Brian
On Thu, Sep 5, 2013 a
Why would you like to do that? The TS7700 is structurally different from
the B20 in that it does much more present the grid as one entity and the
reasons for your B20 control will probably not be valid anymore for the
TS7740. You will probably can, but don't need to anymore.
Kees.
-Original M
Hello Kees-san,
As far as I know, cleaner cartridges in TS3500 (3494) is NOT belong to
any Logical Lbrary of TS3500 which is used for TS7740 or IBM 3494/VTS.
As Wood-san mentioned, D SMS,LIBRARY(lib-name),DETAIL command for
TS3500 does NOT contain cleaner cartridge information.
So OP0008 and OP04
"Mike Wood" wrote in message
news:<9338247828173738.wa.mwwoodntlworld@listserv.ua.edu>...
> Kees, I dont know of good interface. The books do mention a CLI
which is available via Java.
http://publib.boulder.ibm.com/infocenter/ts3500tl/v1r0/index.jsp?topic=%
2Fcom.ibm.storage.ts3500.doc%2Fipg
Kees, I dont know of good interface. The books do mention a CLI which is
available via Java.
http://publib.boulder.ibm.com/infocenter/ts3500tl/v1r0/index.jsp?topic=%2Fcom.ibm.storage.ts3500.doc%2Fipg_3584_cli.html
OAM provides possible alternatives:
1. D SMS LIBRARY(),DETAIL output contains a