Classification: Confidential
TSO BPXMTEXT E329 will ive you some answers and possible corrections
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Gadi Ben-Avi
Sent: Thursday, July 20, 2023 2:46 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Problem running GIMUNZIP
I think it's related.
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Andrew Rowley
Sent: יום ה 20 יולי 2023 14:05
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Problem running GIMUNZIP job.
Maybe this problem?
https://community.rocketsoftware.com/discussion/mini
started working.
Gadi
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Colin Paice
Sent: יום ה 20 יולי 2023 11:35
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Problem running GIMUNZIP job.
I do not see //SYSOUT or //SYSPRINT in your JCL... try adding them.
//SYSPRINT DD
: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: Problem running GIMUNZIP job.
I do not see //SYSOUT or //SYSPRINT in your JCL... try adding them.
//SYSPRINT DD SYSOUT=* etc
You might try adding ECHO 'BLAH' to the script so you know something will be
displayed Colin
On Thu, 20 Jul 2023 at 08:46
I do not see //SYSOUT or //SYSPRINT in your JCL... try adding them.
//SYSPRINT DD SYSOUT=* etc
You might try adding ECHO 'BLAH' to the script so you know something will
be displayed
Colin
On Thu, 20 Jul 2023 at 08:46, Gadi Ben-Avi wrote:
> Hi,
> We are in the process of installing z/OS v2.5 fro
Hi,
We are in the process of installing z/OS v2.5 from z/OSMF.
One of the first jobs uses GIMUNZIP to create the new z/OS libraries.
When the job got to the SMPPTS library, we got these messages:
GIM43501S ** THE CALL TO THE BPX1WRT SERVICE FAILED WHEN PROCESSING
/tmp/izud-V110AVN-T13