Re: PPRC power failure

2019-02-14 Thread Steve Horein
For messaging, review of Message Flood Automation rules would seem to be in order: https://www.ibm.com/support/knowledgecenter/SSLTBW_2.2.0/com.ibm.zos.v2r2.ieae200/msgfld.htm On Wed, Feb 13, 2019 at 9:44 PM Peter wrote: > Hi > > One of our DS box in DR had a power failure last night and our pr

Re: PPRC power failure

2019-02-14 Thread Richards, Robert B.
] On Behalf Of Peter Sent: Wednesday, February 13, 2019 10:44 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: PPRC power failure Hi One of our DS box in DR had a power failure last night and our production LPARS logon got impacted . When I checked up the RMF i saw many DASD devices were overloaded and

Re: PPRC power failure

2019-02-14 Thread Mike Schwab
On the sending DASD there is a 1 bit per track table of updated tracks. When each track is sent the bit is reset. When it gets caught up it sets a sync point. On Wed, Feb 13, 2019 at 9:44 PM Peter wrote: > > Hi > > One of our DS box in DR had a power failure last night and our production > LPAR

PPRC power failure

2019-02-13 Thread Peter
Hi One of our DS box in DR had a power failure last night and our production LPARS logon got impacted . When I checked up the RMF i saw many DASD devices were overloaded and flood of PPRC error messages too in SYSLOG. Once we fixed the power failure and re-established the replication the logins a