Re: Logrec Logstream name

2019-05-15 Thread Gadi Ben-Avi
Thanks everyone, Gadi -Original Message- From: IBM Mainframe Discussion List On Behalf Of Allan Staller Sent: Wednesday, May 15, 2019 3:39 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Logrec Logstream name In the logger policy, and IIRC, in LOGREC= in IEASYS00. HTH, -Original

Re: Logrec Logstream name

2019-05-15 Thread Allan Staller
In the logger policy, and IIRC, in LOGREC= in IEASYS00. HTH, -Original Message- From: IBM Mainframe Discussion List On Behalf Of Gadi Ben-Avi Sent: Wednesday, May 15, 2019 7:35 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Logrec Logstream name Thanks Where do I define the name of the

Re: Logrec Logstream name

2019-05-15 Thread Allan Staller
logstream. HTH -Original Message- From: IBM Mainframe Discussion List On Behalf Of Gadi Ben-Avi Sent: Wednesday, May 15, 2019 6:57 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Logrec Logstream name Hi, We have a basic sysplex with two members. There is no coupling facility. 1. Is it

Re: Logrec Logstream name

2019-05-15 Thread Mike Shorkend
esday, May 15, 2019 3:29 PM > To: IBM-MAIN@LISTSERV.UA.EDU > Subject: Re: Logrec Logstream name > > Gadi > If you do not have a coupling facility, them the logstream has to be DASD- > only and can not be shared between LPARS. See here: > > > https://www.ibm.com/suppo

Re: Logrec Logstream name

2019-05-15 Thread Gadi Ben-Avi
Thanks Where do I define the name of the logstream for LOGREC? Gadi -Original Message- From: IBM Mainframe Discussion List On Behalf Of Mike Shorkend Sent: Wednesday, May 15, 2019 3:29 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Logrec Logstream name Gadi If you do not have a coupling

Re: Logrec Logstream name

2019-05-15 Thread Mike Shorkend
Gadi If you do not have a coupling facility, them the logstream has to be DASD- only and can not be shared between LPARS. See here: https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.3.0/com.ibm.zos.v2r3.ieag200/cfod.htm You will need to use a unique name for each logstream. You could use th

Logrec Logstream name

2019-05-15 Thread Gadi Ben-Avi
Hi, We have a basic sysplex with two members. There is no coupling facility. 1. Is it possible to use the same logrec logstream (SYSPLEX.LOGREC.ALLRECS) for both systems. 2. If not, how do I specify different a logstream for each system? We are using z/OS v2.3 Gadi -