Brian and Ravi Thank-you. What you describe does indeed seem to be what I
am seeing.
On Thu, Jan 31, 2019 at 12:42 AM Ravi Gaur wrote:
> We have seen this while z13 migration to z14 specially with the cable swa=
> ps for OSA ICC weren't showing active with SE and eventually with the POR=
> (act
We have seen this while z13 migration to z14 specially with the cable swaps for
OSA ICC weren't showing active with SE and eventually with the POR (activate)
for CEC brought them back online . It wasn't in the list as a activity to do
but now with every cable swap we added POR activity ...not pr
I think the OAS-ICC has a setting that can be used to tell it to hang on to a
session for x-minutes, a POR would reload the OSA, so things would tend to
reset immediately.
It's should be just a parm change to the ICC definitions for the consoles that
you are using.
Brian
---
I can work around this, but would like to understand.
Running a z9 and zOS 1.13. We use Rocket software Bluezone 3270 emulations
on Win-PC for consoles. This works just fine during an IPL.
However when we do a POR, they do not reconnect immediately. I have
worked around this using the HMC mas