Re: RMM Extended Format Record Layout

2021-09-29 Thread Jordi Bornay
hello Robert I am interested in the subject, since soon I must install the product and use cartridges with a capacity of 8000 -> 400. Any progress you have made (jcl's, installation tips, ... etc) will be very helpful. Regards -

Re: Low softcapping on high capacity CEC

2021-06-30 Thread Jordi Bornay
OA60641: GROUP CAPACITY LIMIT IS NOT PROPERLY ENFORCED WHEN THE SYSTEM HAS ABSMSUCAPPING ACTIVE AND THERE IS NO DEFINED CAPACITY LIMIT Group Capacity limit not properly enforced at z/OS 2.3 when Group Capping and Absolute MSU Capping are both active and there is no defined capacity limit. When AB

SMF - SIGVALIDATE parameter

2021-05-19 Thread Jordi Bornay
SIGVALIDATE is for checking digital signature on SMF records. How should this help to find out if smf records of a subtype are missing for a time interval ? -- For IBM-MAIN subscribe / signoff / archive access instructions, send

Re: RMM byte usage

2021-02-08 Thread Jordi Bornay
SOLVED //ICETOOL EXEC PGM=ICETOOL,REGION=1024K //TOOLMSG DD SYSOUT=* //DFSMSG DD SYSOUT=* //SHOWDEF DD SYSOUT=* //OCCRPT DD SYSOUT=

Re: RMM byte usage

2021-02-08 Thread Jordi Bornay
thank you ... but I want a list of all volumes and their occupation. for the panel, I only get 1 volume and for REPORT5 that of the datasets. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists..

Re: RMM byte usage

2021-02-08 Thread Jordi Bornay
I come across a similar case, but my goal is to know the total bytes used or the percentage of cartridge used. I've searched for topics and I've only found this one from REPORT5, which doesn't work for me. I've looked in the DFrmm manual and couldn't see anything. Can somebody help me? thanks --

Re: Offsets SMF17

2020-11-06 Thread Jordi Bornay
grande Max. grazie mille -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: Offsets SMF17

2020-11-06 Thread Jordi Bornay
hi, modified... DISPLAY FROM(SMF) LIST(SMFREP) - TITLE('SMF-17 : WHO DELETED DATASETS') DATE TIME PAGE - HEADER('SMF') ON(6,1,BI) - HEADER('SYS') ON(14,4,CH) -SMF17SID HEADER('DATE') ON(10,4,DT1,E'/99/99') - SM

Re: Offsets SMF17

2020-11-06 Thread Jordi Bornay
thank's I will review the INCLUDE to see if it is what you say. (My background is not that ...) OPTION STOPAFT=1000 INCLUDE COND=(6,1,BI,EQ,X'11',AND,45,4,CH,EQ,C'UCAT') 0021000 SORT FIELDS=(11,4,CH,A,7,4,CH,A)

Offsets SMF17

2020-11-06 Thread Jordi Bornay
hi, It may be a small detail, but sometimes when you think about it a lot, you don't see it. I want to make a list of the files that have been deleted, from SMF record 17, and it must be offsets but nothing comes out. can you help me? Thank's jcl: //SYMBOLS INCLUDE MEMBER=SYMBOLS

Re: How to configure LOADxx in DR

2020-05-21 Thread Jordi Bornay
yes, but the error that comments (00F) is because it cannot find the IPL text. -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: How to configure LOADxx in DR

2020-05-21 Thread Jordi Bornay
hello have you put the IPL text in the volume .. ?? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: Grid To Grid Migration - GGM

2019-07-10 Thread Jordi Bornay
Hi Tom Will you quiesce all activity to all of the volumes while you take the backups so that the data will be consistent? to make the copy of the volume I will use the DFdss ... and it will be sent to VTS. This virtual volume will not be updated, as the GGM requires. Therefore, I understand t

Re: Grid To Grid Migration - GGM

2019-07-10 Thread Jordi Bornay
I'm sorry to explain myself so badly it is about copying all the discs of a lpar of a CPD, with which I do not share anything. I'm limited by cost issue. Due to the old hardware in origin, I would need an additional card in my hardware (more modern) to be able to read the cartridges. shortly, I

Re: Grid To Grid Migration - GGM

2019-07-10 Thread Jordi Bornay
f it had a connection between the two disk booths, it could use Global Copy, but there is no means to establish a PPRC. They are two isolated centers, and I can not make a cartridge copy and restore because I need a card. and the project budget is limited ---

Re: Grid To Grid Migration - GGM

2019-07-10 Thread Jordi Bornay
yes, the idea is to copy discs from one CPD to another that does not have any connection between them (soon a data line) -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu wi

Grid To Grid Migration - GGM

2019-07-10 Thread Jordi Bornay
Hello, I have to copy almost 300 discs of different capacities (mod-9, mod-27 ...) with the GGM tool. I have in both centers, VTS and tape library. any advice? recommendation? example of jcl for the mass transfer of jobs to the copy queue? It's the first time I'm going to use this technique, so a

Re: ISPF temporary files

2019-05-28 Thread Jordi Bornay
**/ WHEN (&DSNEQ &FTS014003)/* CON MC TS014003. */ DO /* BACKUP =1 COPIAS */ SET &MGMTCLAS = 'TS014003'/* EXPIR. = 40 DIAS