Dear GROMACS users,
While simulating a DLPC membrane, I noticed that it tends to diffuse along
the normal (Z-axis) component. Is there a 'standard' restrain that is used
to prevent such diffusion?
The first option I thought was to restrain the center of mass of the whole
membrane along the Z-axis
9:04 PM, Mark Abraham wrote:
> On 23/02/2012 10:26 AM, Jose Borreguero wrote:
>
> Dear GROMACS users,
>
> While simulating a DLPC membrane, I noticed that it tends to diffuse along
> the normal (Z-axis) component. Is there a 'standard' restrain that is used
> to prev
remove the COM momentum in this case?
-Jose
On Thu, Feb 23, 2012 at 8:35 AM, Mark Abraham wrote:
> On 23/02/2012 10:27 PM, Jose Borreguero wrote:
>
> I am not referring to any drift of the whole system, but to the diffusion
> of the lipid bilayer only. Diffusion of molecules in wa
Dear Gromacs users,
Is there any algorithm/procedure to calculate NOEs from an MD trajectory?
I'd greatly appreciate any references where the algorithm is described.
Best regards,
Jose M. Borreguero
--
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-
Dear Gromacs users,
I'm new to gromacs. I want to simulate a short peptide in an implicit
solvent with low dielectric constant (simulate the interior of a membrane).
Can you please tell me which implicit solvent force field is more suitable,
and how do I pass the value of the dielectric constant ?
Dear Gromacs users,
Im new to gromacs and I'm following a tutorial (
http://nmr.chem.uu.nl/~tsjerk/course/molmod/). Unfortunately, the tutorials
doesn't say anything about how to update the topology file after using
'genion' to replace a few water molecules with ions.
I manually edited the topolog
ne 7228 of protein.top is the last line of the
file, that is,
CL 23
So the error message is not much help :(
-Jose
On Wed, Dec 7, 2011 at 11:04 AM, Justin A. Lemkul wrote:
>
>
> Jose Borreguero wrote:
>
>> Dear Gromacs users,
>>
>> Im new to gromacs and I'
ls :D (
http://www.bevanlab.biochem.vt.edu/Pages/Personal/justin/gmx-tutorials/index.html)
I'll give a try with the Lyzosyme one!
- Jose
On Wed, Dec 7, 2011 at 1:29 PM, Justin A. Lemkul wrote:
>
>
> Jose Borreguero wrote:
>
>> Hi Justin, thanks for your reply!
>>
>> I appended
gt; paragraph was not edited or added.
>
> Although I feel personally addressed, I can add that you're not the
> first to respond to the tutorial like this. It is common behaviour for
> a subset of undergrad students that had to follow this course as part
> of their curriculum
Dear GROMACS users,
I am simulating aqueous isopropanol. Unfortunately I observe segregation of
isopropanol from SPC water at isopropanol fraction volume of 0.25. Since
isopropanol is miscible in water, my parameters stress too much the
hydrophobic character of this solute. Only a few interstitial
0.106023
"HA2" 0.038591
"HA3" 0.038591
"O1"-0.579340
"HO1" 0.373996
And the VdW radii and epsilon:
HC 1.3770 0.0150
OH 1.7210 0.2104
CT 1.9080 0.1094
HO 0.0 0.0
On Fri, Mar 5, 2010 a
11 matches