Dear David,
Thank you very much!!
Your suggestion works!! After removing water and ion from my
structure, I did normal mode analysis successfully!!
I appreciate your help.
Shen
在 2012年3月17日 下午11:45,Justin A. Lemkul 写道:
>
>
> qiancheng shen wrote:
>
>> Dear David,
>>
Dear Gromacs users,
I ran a simulation with 13 Hypericin molecules in water for 10 ns and 7 of them
formed an aggregate.Is there any way to find out between what molecules and
atoms Hbonds were formed?
Thanks in advance
Hovakim Grabski
Russian-Armenian(Slavonic) University
--
gmx-users mailing
Hovakim Grabski wrote:
Dear Gromacs users,
I ran a simulation with 13 Hypericin molecules in water for 10 ns and 7
of them formed an aggregate.Is there any way to find out between what
molecules and atoms Hbonds were formed?
Yes, see the various options that g_hbond provides, particularly -
Newbie here.
I'm trying to install Gromacs and I'm following the instructions at the
following link:
http://www.gromacs.org/Downloads/Installation_Instructions
The problem is when I type
./configure --enable-float
It gives me 'No such file or directory'
I even tried
./configure --enable-fl
Suhaila Haji Mohd Hussin wrote:
Newbie here.
I'm trying to install Gromacs and I'm following the instructions at the
following link:
http://www.gromacs.org/Downloads/Installation_Instructions
The problem is when I type
./configure --enable-float
It gives me 'No such file or directory'
> Date: Sun, 18 Mar 2012 12:35:26 -0400
> From: jalem...@vt.edu
> To: gmx-users@gromacs.org
> Subject: Re: [gmx-users] Problem Installing Gromacs
>
>
>
> Suhaila Haji Mohd Hussin wrote:
> > Newbie here.
> >
> > I'm trying to install Gromacs and I'm following the instructions at the
> > foll
Dear All --
I have a system of the liquid/vapor interface kind. The droplet of
liquid with a radius of about 10nm is surrounded by a volume of vacuum
of ~1000nm^3. What is the best method among those currently in
GROMACS4 to treat electrostatics in this case?
Dr. Vitaly V. Chaban, 430 Hutchison
Hello.
I already installed fftw3. After unpacking it, I install via the following:
./configure
make
make install
But after that the instructions are not clear to me. Like, it's not telling
where do I download Gromacs tar?
Or do I need to type some command from fftw so that Gromacs sho
OK. I downloaded Gromacs 4.5.5. Unpacked it then type
./configure
configure: error: Cannot find fftw3f library
But I already install fftw3 properly.
What is happening?
Cheers,
Suhaila.
From: bell_beaut...@hotmail.com
To: gmx-users@gromacs.org
Subject: Problem installing Gromacs: What next?
D
Suhaila Haji Mohd Hussin wrote:
Hello.
I already installed fftw3. After unpacking it, I install via the following:
./configure
make
make install
But after that the instructions are not clear to me. Like, it's not
telling where do I download Gromacs tar?
Or do I need to type some
Suhaila Haji Mohd Hussin wrote:
OK. I downloaded Gromacs 4.5.5. Unpacked it then type
./configure
configure: error: Cannot find fftw3f library
But I already install fftw3 properly.
What is happening?
The commands below will install double-precision fftw, but Gromacs is single
precision
Please be sure to keep the discussion on the mailing list and not my personal
email.
You may need to specify the location of the fftw installation using LDFLAGS and
CPPFLAGS for the libraries and headers, respectively. See example usage at:
http://www.gromacs.org/Documentation/Installation_
Dear All,
I am practicing the on-line tutorial
http://www.nmr.chem.uu.nl/~tsjerk/course/md-tutorial/.
In the step "mdrun -v -deffnm 1LW9-EM-solvated" of "Energy minimization of the
solvated system", it says "
Converged to machine precision , but not to the requested precision Fmax < 1".
Bef
Acoot Brett wrote:
Dear All,
I am practicing the on-line tutorial
http://www.nmr.chem.uu.nl/~tsjerk/course/md-tutorial/.
In the step "mdrun -v -deffnm 1LW9-EM-solvated" of "Energy minimization
of the solvated system", it says "
Converged to machine precision , but not to the requested pr
Hi Mark,
Thanks - I completely forgot about that!
Cheers,
Huiwen
From: gmx-users-boun...@gromacs.org [mailto:gmx-users-boun...@gromacs.org] On
Behalf Of Mark Abraham
Sent: Sunday, March 18, 2012 2:03 PM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization of crysta
Dear All,
The problem really occurs in the ion addition step.
In order to keep 0.1 M ion concentration, 20 Na+ and 20 C1- were added. In
order to keep 0 charge, 8 Cl- were added.
From the .gro file, 48 water (72 H and 48 O) were deleted in order to add the
38 charges, which makes there was
Hi Acoot,
Read the tutorial. It's explained there... Mind that that tutorial was
written for an earlier version of Gromacs and some things have changed. The
names of ions, for instance.
Cheers,
Tsjerk
On Mar 19, 2012 6:40 AM, "Acoot Brett" wrote:
Dear All,
The problem really occurs in the io
17 matches
Mail list logo