Hello all!
I would like to insert a molecule to a membrane system and would like to
start from a specific position of the molecule (hydrocarbon or lipid
headgroups). I tried doing that in Pymol after converting the merged gro
into pdb (using editconf) but when I saved the file in Pymol the order of
Hi,
Perhaps you can do just like you did in pymol, but isntead of saving the
file, mearly write down the coordinates of the newborn water and enter
it into your gro-file.
Cheers,
Erik
Adva Suez skrev 2010-12-01 08.59:
Hello all!
I would like to insert a molecule to a membrane system and wo
Hi Gromacians
I am planning to compute the standard error for the interfacial surface
tension of water-dichloro ethane. i just want to know is my procedure right.
below is the result what i get from my g_energy command.
Statistics over 51 steps [ 0. thru 1000.0001 ps ], 1 data sets
All av
On 1/12/2010 7:59 PM, vinothkumar mohanakrishnan wrote:
Hi Gromacians
I am planning to compute the standard error for the interfacial
surface tension of water-dichloro ethane. i just want to know is my
procedure right. below is the result what i get from my g_energy command.
Statistics over
Dear Gromacs-users,
Could anyone tell me why some analysis-tools as for example anadock,
g_clustsize and others are not described any more
in the online-manual? Could that mean that these tools are not supported any
more by the Gromacs community or one should not use them because of possible
b
Dear Mark
Thank you for your explaination but Its not clear to me what you are trying
to say. can you explain it bit more clearly. what should i need to do to get
the standard error? any help is highly appreciated.
Regards
Vinoth
On Wed, Dec 1, 2010 at 2:39 PM, Mark Abraham wrote:
> On 1/12/201
Emanuel Peter wrote:
Dear Gromacs-users,
Could anyone tell me why some analysis-tools as for example anadock,
g_clustsize and others are not described any more
in the online-manual? Could that mean that these tools are not supported
any more by the Gromacs community or one should not use the
Adva Suez wrote:
Hello all!
I would like to insert a molecule to a membrane system and would like to
start from a specific position of the molecule (hydrocarbon or lipid
headgroups). I tried doing that in Pymol after converting the merged gro
into pdb (using editconf) but when I saved the fi
Dear gromacs users,
I am running NVT simulations for polarizable (shell particle) water model
(GROMACS version 4.5.1 and 4.5.3 (issue is same in both)) using v-rescale
thermostat.
While temperature, potential, kinetic and total energies behave quite well I am
failing to obtain constant values
Hi, everyone
I find that i used T and P coupling in water-air interface, that is the reason
my system imploded.
So i changed to NVT. But there are still fatal errors.
I have some questions concerning .gro file.
for example in spc216.gro, there are both + and - psotions. But in other .gro
Dear All,
I have the following error, for both mpi and normal mdrun modes. I tried both
using a pull group for the first time, but when the error persisted, went back
and used data/md.mdp files which I know work as a test and get the same errors.
> >
> > [anode27:16555] *** Process received si
Hi,
The integrator is not the issue. The cut-off setup is.
You should use interactions that go smoothly to zero with a buffer region in
the neighborlist.
Use for instance shift for LJ interactions. PME could be switched, but that is
a much smaller
contribution. Use rlist about 0.3 nm larger th
Dear All, (this is a repost as I included no subjectline)
I have the following error, for both mpi and normal mdrun modes. I tried both
using a pull group for the first time, but when the error persisted, went back
and used data/md.mdp files which I know work as a test and get the same errors.
lloyd riggs wrote:
Dear All, (this is a repost as I included no subjectline)
I have the following error, for both mpi and normal mdrun modes. I tried both
using a pull group for the first time, but when the error persisted, went back
and used data/md.mdp files which I know work as a test an
I ran the simulation using a different force field ffG53a6. I modified
the ffG53a6nb.itp file by changing the term C6 to zero for nonbonded
parameters, but this time for urea in water. The simulation ran fine
without any warning or exploding. I don't understand why it would work
with one fo
nishap.pa...@utoronto.ca wrote:
I ran the simulation using a different force field ffG53a6. I modified
the ffG53a6nb.itp file by changing the term C6 to zero for nonbonded
parameters, but this time for urea in water. The simulation ran fine
without any warning or exploding. I don't understand
I see. I actually want to compare my RDFs with C6 term off. Earlier I
tried using force.c code file and turned C6 = 0, but when i compared
my RDFs, it didn't look any different so I am not sure if it even
worked at all or made any difference to the simulation, but again I
was using OPLS-AA
On 1/12/2010 8:25 PM, vinothkumar mohanakrishnan wrote:
Dear Mark
Thank you for your explaination but Its not clear to me what you are
trying to say. can you explain it bit more clearly. what should i need
to do to get the standard error? any help is highly appreciated.
Like I said, you need
On 2/12/2010 12:30 AM, 铁锋 彭 wrote:
Hi, everyone
I find that i used T and P coupling in water-air interface, that is
the reason my system imploded.
So i changed to NVT. But there are still fatal errors.
I have some questions concerning .gro file.
for example in spc216.gro, there are both + and
Hi,
Maybe it is not so clear from the topology table in the manual, but when you
supply
sigma and epsilon as non-bonded parameters, as for OPLS, the nonbond_params
section also expects sigma and epsilon.
So it seems you could not set only C6 to zero.
However there is an, undocumented, trick: if
I am going to give that a try. Thanks.
Quoting Berk Hess :
Hi,
Maybe it is not so clear from the topology table in the manual, but
when you supply
sigma and epsilon as non-bonded parameters, as for OPLS, the nonbond_params
section also expects sigma and epsilon.
So it seems you could not
Dear All,
> If you suspect a faulty installation, then you need to post more
> information, like:
>
> - compilers used
> - cmake or autoconf?
> - hardware
> - commands used to install
>
> -Justin
>
> > Sincerely
> >
> > Stephan Watkins
> >
Compilers are all standard gnu compilers
I used au
Would I change the sigma to negative in my nb.itp file the way it is
set or do I need to include a [nonbond_params] section and make sigma
negative in that specific section? because I realize from the manual
OPLS-AA uses combination rule 3 but in the manual it shows to combine
sigma for i a
Dear Gromacs users,
I am trying to use CHARMM27 taking the simulation conditions of two recent
articles as guides in optimizing the simulation parameters. (DOI:
10.1021/ct900549r and DOI: 10.1021/jp101581h).
-- Both are using PME for electrostatics and I am planning to do that too
-- Both ha
Hello,
Is there a function that allows users to read a trajectory file and
print it in a readable format (like gmxdump) but starting from a user-
specified frame rather than from 0?
Thanks in advance,
Silvia Crivelli
--
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org
Hi,
you can use trjconv to write frames to GRO format. Or you can use it to
write a trajectory from a different starting point (and then you can use
gmxdump).
Roland
On Wed, Dec 1, 2010 at 4:39 PM, Silvia Crivelli wrote:
> Hello,
>
> Is there a function that allows users to read a trajectory fi
On Wed, Dec 1, 2010 at 4:30 PM, Hassan Shallal wrote:
> Dear Gromacs users,
>
> I am trying to use CHARMM27 taking the simulation conditions of two recent
> articles as guides in optimizing the simulation parameters. *(DOI:
> *10.1021/ct900549r
> and *DOI:* 10.1021/jp101581h).
>
> -- Both are u
I have some issues to discuss with the mailing list users,
1- Is using virtual sites alone enough to allow me to lengthen the time step
from 2 fs to 4 fs, or I have also to use heavy hydrogens when creating topology
files in order to use 4 fs time step?
2- Another question, does vitual sites
On 2/12/2010 11:13 AM, Hassan Shallal wrote:
I have some issues to discuss with the mailing list users,
1- Is using virtual sites alone enough to allow me to lengthen the time step
from 2 fs to 4 fs, or I have also to use heavy hydrogens when creating topology
files in order to use 4 fs time s
On 2/12/2010 7:40 AM, nishap.pa...@utoronto.ca wrote:
Would I change the sigma to negative in my nb.itp file the way it is
set or do I need to include a [nonbond_params] section and make sigma
negative in that specific section? because I realize from the manual
OPLS-AA uses combination rule 3 b
Hi,
I know it looks a little bit strange, but i was trying to restrain
just some water in my system.
Now, if i put something like
[ position_restraints ]
; i funct fcxfcyfcz
11 1000 1000 1000
I put restraints on all the molecules.
I thought about a tu
> Hi, everyone
>
> I find that i used T and P coupling in water-air interface, that is the
> reason my system imploded.
>
> So i changed to NVT. But there are still fatal errors.
>
> I have some questions concerning .gro file.
>
> for example in spc216.gro, there are both + and - psotions. But in
On 2/12/2010 12:51 PM, Guido Polles wrote:
Hi,
I know it looks a little bit strange, but i was trying to restrain
just some water in my system.
Now, if i put something like
[ position_restraints ]
; i funct fcxfcyfcz
11 1000 1000 1000
I put restrai
Dear GMXers,
I'm running a simulation of water contact angle measurement on top of
graphite surface.
Initially a water cubic box is placed on two-layer graphite surface with the
rest of the box being vacuum. The water droplet is relaxed during the
simulation to develop a spherical shape.
An error
On 2/12/2010 4:16 PM, WU Yanbin wrote:
Dear GMXers,
I'm running a simulation of water contact angle measurement on top of
graphite surface.
Initially a water cubic box is placed on two-layer graphite surface
with the rest of the box being vacuum. The water droplet is relaxed
during the simula
35 matches