On 11/3/13 6:20 AM, kiana moghaddam wrote:
Dear Justin
Further to your previous email, I want to calculate free energy for DNA-ligand
interaction. According to your answer, for more sensitive calculations like free
energy simulations and normal modes, emtolshould be lower than 1. As
I understa
On 11/2/13 3:38 PM, kiana moghaddam wrote:
Hi GMX Users
I 'm running MD Simulation for DNA-ligand interaction. I ran energy
minimization with emtol=10, 100 and 250 in 1 steps (steepest descent
followed by the conjugate gradient algorithm). The lowest value for energy
obtained for emtol=
Hi GMX Users
I 'm running MD Simulation for DNA-ligand interaction. I ran energy
minimization with emtol=10, 100 and 250 in 1 steps (steepest descent
followed by the conjugate gradient algorithm). The lowest value for energy
obtained for emtol=10.
I have some questions about energy minimiz
February 2010 12:06 AM
To: gmx-users@gromacs.org
Subject: [gmx-users] energy minimization problem
Hi ,
I have a protein with 2 chains. I need to do normal mode analysis on it. As
there are no
covalent bonds between the two chains, I did not use the "merge" option in the
"pdb2gmx&q
Hi ,
I have a protein with 2 chains. I need to do normal mode analysis on it.
As there are no
covalent bonds between the two chains, I did not use the "merge" option in the
"pdb2gmx"
command.
I am trying to energy minimize the structure , in vaccum.( in double precision)
, but am not
a
Josiah Zayner wrote:
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of David van der Spoel
Sent: Sunday, June 24, 2007 4:18 AM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization problem with Double precision
andmpi
Josiah
> -Original Message-
> From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
> On Behalf Of David van der Spoel
> Sent: Sunday, June 24, 2007 4:18 AM
> To: Discussion list for GROMACS users
> Subject: Re: [gmx-users] Energy minimization problem with Double precision
&g
Josiah Zayner wrote:
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of David van der Spoel
Sent: Saturday, June 23, 2007 4:36 PM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization problem with Double precision
andmpi
Josiah
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of David van der Spoel
Sent: Saturday, June 23, 2007 4:36 PM
To: Discussion list for GROMACS users
Subject: Re: [gmx-users] Energy minimization problem with Double precision
andmpi
Josiah Zayner wrote:
>
urday, June 23, 2007 1:05 PM
To: gmx-users@gromacs.org
Subject: [gmx-users] Energy minimization problem with Double precision and
mpi
Each time I try to run mdrun with double precision and more than one node, I
always receive some atom with infinite Fmax, no matter what I do, Always on
Step=0
I managed to install mdrun_d from CVS and the problem is fixed
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
On Behalf Of Josiah Zayner
Sent: Saturday, June 23, 2007 1:05 PM
To: gmx-users@gromacs.org
Subject: [gmx-users] Energy minimization problem with Double
Each time I try to run mdrun with double precision and more than one node, I
always receive some atom with infinite Fmax, no matter what I do, Always on
Step=0. The strangest thing is that it still attempts the minimization but
the values never change except for Dmax in a steepest descent. If I cha
Hi Arun,
You have to get your methods straight.., and be more clear in the
phrasing of your question.
I am trying to simulate a surfactant-water
system(also contains some co-surfactants). Surfactant is a cationic
surfactant with chloride as counterion. And the cosurfac
Dear gmx-users:
I am trying to simulate a surfactant-water
system(also contains some co-surfactants). Surfactant is a cationic
surfactant with chloride as counterion. And the cosurfactant is fatty
alcohol. water is of spc model. I got topologies from Prodrg for my
surfactan
George Abadir wrote:
Thanks guys for your replies. The problem is that the potential energy
is "too" low: it can't be true I think. Also, the high force means that
the system is not really stable (at least the atom influenced by this
force is not!). And yes I defined flexible for the water mole
Thanks guys for your replies. The problem is that the potential energy
is "too" low: it can't be true I think. Also, the high force means that
the system is not really stable (at least the atom influenced by this
force is not!). And yes I defined flexible for the water molecules.
I don't know if
19 apr 2007 kl. 03.45 skrev Venky Krishna:
Hi George,
I usually delete/move the molecules reported to have high force
values in the minimization steps. A better thing would be to start
with a box which has sufficient intermolecular distance again by
deleting molecules which are very clos
Hi George,
I usually delete/move the molecules reported to have high force
values in the minimization steps. A better thing would be to start
with a box which has sufficient intermolecular distance again by
deleting molecules which are very close to each other (use the
g_mindist program)
Hi,
I am doing an energy minimization for a carbon nanotube (end capped
with hydrogen atoms) in a box of water. I get the following message:
" Stepsize too small, or no change in energy.
Converged to machine precision,
but not to the requested precision Fmax < 10
Double precision normally
Hello,
I recently obtained (from DvS) the .itp file for the SSWM4-DP
polarizable water molecule, and a corresponding set of water box
coordinates.
I use double precision executables in all of the calculations mentioned
below.
I ran an energy minimization on this box of water, then a 500ps
On Mon, 17 Apr 2006 08:21:35 -0400 (EDT)
"Robson P. S. Peguin" <[EMAIL PROTECTED]> wrote:
Hi everybody,
I'm trying to simulate an interfacial system using
Gromacs. My simulation box has water in one side and
hydrofluorocarbon in the other side. This system was
successfully tested using DL-PO
Robson P. S. Peguin wrote:
Hi everybody,
I'm trying to simulate an interfacial system using Gromacs. My simulation box
has water in one side and hydrofluorocarbon in the other side. This system was
successfully tested using DL-POLY simulation package previously. Also, the box
containing pure
Hi everybody,
I'm trying to simulate an interfacial system using Gromacs. My simulation box
has water in one side and hydrofluorocarbon in the other side. This system was
successfully tested using DL-POLY simulation package previously. Also, the box
containing pure hydrofluorocarbon worked fin
23 matches