Pressure should fluctuate significantly. The estimator for the
pressure that is generally used is very noisy. The question is, do the
pressure averages over, say, 500 ps or 1 ns look about right?
On Sun, Aug 25, 2013 at 5:07 PM, Mark Abraham wrote:
> On Sun, Aug 25, 2013 at 6:22 PM, rahul seth
>
On Sun, Aug 25, 2013 at 6:22 PM, rahul seth
wrote:
> Hi All,
>
> I have been trying to perform NPT-REMD with a Protein Substrate and water.
> I am trying to use md+nose-hoover thermostat and parrinello-rahman
> barostat. However, I am not quite sure about the tau-t and the tau-p that I
> should be
Hi All,
I have been trying to perform NPT-REMD with a Protein Substrate and water.
I am trying to use md+nose-hoover thermostat and parrinello-rahman
barostat. However, I am not quite sure about the tau-t and the tau-p that I
should be using here. I paste a part of my mdp file below:
define
Hello everyone, I'm trying to perform REMD simulation at NPT emsemble.
Here I have some question.
1) Using parrinello-rahman pressure coupling, REMD simulation is unstable at
high temperature.
(highest temperature ~400K).
2) Using berendsen T-coupling and P-coupling scheme..(tau_t = 0.1ps
4 matches