Thanks, Vasilii.
>From publ it's clear that 5 a.u. is standart for all CP MD
simulations, I was confused by examples from Biswas page :) It's time
to start cp md and will go deeper in theory :)
On Mon, Apr 7, 2008 at 9:39 PM, Vasilii Artyukhov <[EMAIL PROTECTED]> wrote:
> Dear Andrey,
>
> The ma
Dear Andrey,
The maximum time step depends on whether you're doing Born-Oppenheimer or
Car-Parrinello MD. In the case of usual BO MD, you normally want a time step
of 0.5-1.0 fs, possibly 2 fs, if you use rigid molecules. In the CP case,
you have to use a much smaller time step to make sure that t
Dear all,
We successfully passed all test with CPMD-gmx and now the time to do
md production runs, In examples from interface home page timestep is
1fs but in CPMD papers time step is much less, about 0.12 fs. Could
you please advise some papers to read? I found only one paper
referencing to CPMD-
3 matches