On 4/28/12 12:28 PM, J B wrote:
Hi,
the distance is 3.89 nm and the z-dimension is roughly 8 nm
Is the problem specific to cylinder geometry? Do other settings work? Does it
make a difference if you set values for pull_r0 and pull_r1?
-Justin
> Date: Sat, 28 Apr 2012 09:18:31 -040
On 4/28/12 2:06 PM, Peter C. Lai wrote:
#2
Generally a good idea to keep the names consistent, however - why are you using
POP in the coordinate file instead of POPC?
If it is a .pdb file, the standard residue name occupies 3 characters. Many
files (including those from Tieleman) are distr
#2
Generally a good idea to keep the names consistent, however - why are you using
POP in the coordinate file instead of POPC?
--
Sent from my Android phone with K-9 Mail. Please excuse my brevity.
Shima Arasteh wrote:
Dear gmx users,
I want to simulate POPC in water. In equilibration step,
Dear gmx users,
I want to simulate POPC in water. In equilibration step, I have to make an
index file. But when I enter this command, I do not know to choose which group
to make a suitable .ndx file which matches the molecule types and molecules
sections in .top file .
The .top file contains t
oops I meant /usr/local/gromacs/bin in PATH
also 4.5.4 has support for threading if compiled that way...Most clusters don't
use it because nodes on separate chassis usually don't support shared memory
with each other. We get really bad performance when using
threading-over-scalemp as compared t
possibly. Make sure PATH includes /usr/local/bin and LD_LIBRARY_PATH includes
the path where libmd_mpi.so and libgmx_mpi.so are located.
try using mdrun -v and > somelogfile after the mpirun line (like mpirun blah
-np 8 mdrun -v -deffnm etcetc > mpilog). the contents of mpilog will tell you
wha
Hi,
Typically, I use Gromacs 4.5.5 compiled with automatic threading. As you
know, automatic threading is awesome because it allows me to start parallel
runs without calling mpirun. So on version 4.5.5, I can start a job on eight
CPUs using simply the command:
mdrun -s topol.tpr -nt 8
However, n
Hi,
the distance is 3.89 nm and the z-dimension is roughly 8 nm
> Date: Sat, 28 Apr 2012 09:18:31 -0400
> From: jalem...@vt.edu
> To: gmx-users@gromacs.org
> Subject: Re: [gmx-users] Umbrella sampling PMF, drug and membrane with
> pull_geometry=cylinder
>
>
>
> On 4/28/12 5:12 AM, J B
On 4/28/12 10:25 AM, James Starlight wrote:
Francesco,
Thanks, I find your aproach very handfull :)
Justin,
in that example I've defined in minim.mdp
This would have been useful to state up front. Your previous question implied
that you didn't know if any special keywords were necessary
Francesco,
Thanks, I find your aproach very handfull :)
Justin,
in that example I've defined in minim.mdp
*disre = simple
**disre_f = 5000
in the topology.top I've included
* [ distance_restraints ]
; ai aj type index type’ low up1 up2 fac
1 10 10 10.18 0.20 0.22 1.0
w
On 4/28/12 10:08 AM, James Starlight wrote:
.. and the main question- what should be in mdp file of such restrained
minimisation ?
Today I've done vry properly minimisation of such system in vacuum with the CG
minimisator and applied disres ( above example ) with big force constant (
disres op
Hi James,
usually I insert by hand a bond in the topology file between the two
atoms and then I minimize.
This bond doesn't cause the generataion of angles and dihedrals, butit
is enough to make the atom closer.
Francesco
Il 28/04/2012 16:08, James Starlight ha scritto:
.. and the main questi
.. and the main question- what should be in mdp file of such restrained
minimisation ?
Today I've done vry properly minimisation of such system in vacuum with the
CG minimisator and applied disres ( above example ) with big force constant
( disres options have been defined in the minim.mdp file ).
On 28/04/2012 4:14 PM, Albert wrote:
hello Mar:
thanks a lot for kind reply.
From the link you you mentioned, it seems that this problem comes
from the MD system itself. However, it goes well in my workstation.
Moreover, I visualized and analyzed the results from my workstation
running, ev
Hello Everyone,
I am trying to pull ligand biotin out of the streptavidin protein.Following
the tutorial Protein ligand complex by Justin ,i have done till energy
minimization step skipping adding solvent and ion step,and skipping
pressure and temperature equilibration.Now how to proceed further t
On 4/28/12 5:12 AM, J B wrote:
Hi.
I am trying to the the PMF of transferring a drug molecule from the aqueous
phase to a lipid bilayer.
In order to minimize the effects of membrane undulations I tried to use
pull_geometry=cylinder.
Whenever I run a short simulation with umbrella sampling st
On 4/28/12 5:41 AM, Acoot Brett wrote:
Dear All,
Will you please tell me a method or a server which can calculate the mean B
factor of all residues in a PDB file?
A simple script to parse out the B-factor field and calculate the average should
do the trick.
-Justin
--
Hi Francesco!
So I must define in the current topology the disres bettwen two S atoms (
in the below example 1 and 10 ) to apply hormonic restains
[ distance_restraints ]
; ai aj type index type’ low up1 up2 fac
1 10 10 10.18 0.20 0.22 1.0
to restrain this atoms within 0.2 nm. Doe
Hi James,
usually people run a minimization using distance restrain on the two atoms
in order to
make them closer.
Then the obtained cnfiguration is used to recalculate the topology.
Francesco
2012/4/28 James Starlight
> Dear Gromacs Users!
>
> I have a model of my protein wich has 4 S-S bounds
Dear Gromacs Users!
I have a model of my protein wich has 4 S-S bounds in the loop regions. So
I want to define in topology all those four S-S linkage.
Unfortunatelly one of that S-S have not been recognised by Gromacs ( Also
I've tried to check this bond in pymol and found that distance between
Dear All,
Will you please tell me a method or a server which can calculate the mean B
factor of all residues in a PDB file?
Cheers,
Acoot --
gmx-users mailing listgmx-users@gromacs.org
http://lists.gromacs.org/mailman/listinfo/gmx-users
Please search the archive at
http://www.gromacs
Hi.
I am trying to the the PMF of transferring a drug molecule from the aqueous
phase to a lipid bilayer.
In order to minimize the effects of membrane undulations I tried to use
pull_geometry=cylinder.
Whenever I run a short simulation with umbrella sampling starting from a
configuration with
22 matches