Yes, this is a bug. I have fixed it in our development version. For
now, you can use your workaround.
On 12/7/2024 1:28 AM, Shen, Qian wrote:
External Email - Use Caution
Hi Dr. Greve and Experts,
I encountered an issue while running the following command to resample
meltzer.nii.gz
External Email - Use Caution
This is a single case, all of my other subjects ran through without a problem.
Thanks!
Mark
Mark Wagshul, PhD
Associate Professor
Gruss Magnetic Resonance Research Center
Albert Einstein College of Medicine
Bronx, NY 10461
Ph: 7
It is probably indirectly related to the large slice thickness. You
might try running recon-all_clinical.sh
On 12/10/2024 11:28 AM, Francesco Lomi wrote:
> External Email - Use Caution
>
> Dear all,
> I am writing you because I would like to know why recon-all on this
> subject exited w
You can invert the gca with somehting like
mri_ca_register -invert-and-save cvs.gca inv.cvs.gca
The apply inv.cvs.gca to map from CVS space back to the native space
On 12/6/2024 3:51 AM, Tanxin Dong wrote:
External Email - Use Caution
To whom this may concern:
Hi, I’ve been working
For mapping to the surface, each surface vertex has an xyz coordiate in
anatomical space. The registration file is used to convert this into the
column, row, slice in the overlay space. The value of the overlay volume
at the CRS is then assigned to that vertex. In your case, the coordinate
is a
On 12/5/2024 10:14 PM, JM wrote:
External Email - Use Caution
Hi FreeSurfer experts,
In our hospital research settings, we collected structural MRI data
from patients while they were admitted for treatment. Some of the
patients were scanned before contrast agent was injected and s