External Email - Use Caution
Thank you so much!
Ting
> On Jun 29, 2018, at 2:10 PM, Douglas Greve wrote:
>
> Yes, for area and volume, no for thickness
>
> On 6/29/18 3:06 PM, Ting Li wrote:
>> External Email - Use Caution
>>
>> Hi FreeSurfer Experts,
>>
>> I would li
External Email - Use Caution
Hi all,
I just switched from FS 5.3 to 6.0 on Gentoo Linux. Previously Freesurfer
worked fine under octave setup (as specified here:
https://mail.nmr.mgh.harvard.edu/pipermail//freesurfer/2012-January/022135.html),
but after the update, when I tried te
External Email - Use Caution
Dear community:
I have a problem with trac-all processing with the tutorial data.
sh-3.2# trac-all -prep -c $TUTORIAL_DATA/diffusion_tutorial/dmrirc.tutorial
INFO: SUBJECTS_DIR is
/Volumes/TOSHIBA_EXT/otros/Académico/Research/image_processing/freesur
Yes, for area and volume, no for thickness
On 6/29/18 3:06 PM, Ting Li wrote:
> External Email - Use Caution
>
> Hi FreeSurfer Experts,
>
> I would like to do the surface analysis among two groups, like the thickness,
> volume and area. When I run the GLM, do I have to consider the eTIV
External Email - Use Caution
Hi FreeSurfer Experts,
I would like to do the surface analysis among two groups, like the thickness,
volume and area. When I run the GLM, do I have to consider the eTIV as a
covariant or not? Thanks a lot!
Best wishes,
Ting
You can create a surface overlay in matlab and display it using
freeview. See
https://gate.nmr.mgh.harvard.edu/safelinks/greve/annotval2surfoverlay.m
To read it into matlab, you can run
pcc = MRIread('pcc.mgh');
You can convert it to text with mri_convert --ascii pcc.mgh outputtextfile
On 6/2
External Email - Use Caution
Yes, that shows up fine.
Mark Wagshul, PhD
Associate Professor
Gruss Magnetic Resonance Research Center
Albert Einstein College of Medicine
Bronx, NY 10461
Ph: 718-430-4011
FAX: 718-430-3399
Email: mark.wags...@einstein.yu.edu
What if you run 'glxgears'? Does it render properly?
Ruopeng
On 06/29/2018 09:50 AM, Mark Wagshul wrote:
Yes, I’m running it with Xming on Windows. Same thing shows up if I
load a volume.
Mark
Mark Wagshul, PhD
Associate Professor
Gruss Magnetic Resonance Research Cen
Hi Chris
can you elaborate a bit? Our intensity normalization is almost entirely an
automated control point finding tool.
cheers
Bruce
On Fri, 29 Jun 2018, Chris Adamson
wrote:
External Email - Use Caution
Freesurfer devs,
I presented an automated control point addi
Hi David
the -3T flag changes the target atlas to one built from 3T data, and also
modifies some of the parameters that are passed to nu_correct, I believe
to make it a bit more aggressive. I think the parameters we use are the
ones suggested here:
https://www.ncbi.nlm.nih.gov/pubmed/19732839
External Email - Use Caution
Hello Experts,
I believe -3T Flag can be used with "recon-all" on scans collected by 3T
scanners. I believe it performs intensity normalization to set white matter
intensity threshold at 110. I am hoping to learn more about the flag option
as it produc
External Email - Use Caution
Yes, I’m running it with Xming on Windows. Same thing shows up if I load a
volume.
Mark
Mark Wagshul, PhD
Associate Professor
Gruss Magnetic Resonance Research Center
Albert Einstein College of Medicine
Bronx, NY 10461
Ph: 718-
This looks like a display artifact. Are you running freeview via some kind of X
Terminal Emulator on Windows? What if you load a volume?
Ruopeng
> On Jun 28, 2018, at 7:33 PM, Mark Wagshul
> wrote:
>
> Hi.
>
> I’m a newbie to Freeview, hoping that this is a simple problem. When I open
>
13 matches