Re: troubles with apcupsd (basic setup)

2005-11-26 Thread Greg Maruszeczka
Dan O'Connor wrote: >>> > > My config file: >>> > > UPSNAME APC_BACKUPS_650 >>> > UPSCABLE 940-0020B >>> > UPSTYPE dumb >>> > DEVICE /dev/cuaa0 >>> > LOCKFILE /var/spool/lock >>> > > ONBATTERYDELAY 10 >>> > > BATTERYLEVEL 20 >>> > MINUTES 5 >>> > TIMEOUT 600 >>> > > > >> Nope. Same thing. > >

Re: troubles with apcupsd (basic setup)

2005-11-25 Thread Dan O'Connor
> > My config file: > > UPSNAME APC_BACKUPS_650 > UPSCABLE 940-0020B > UPSTYPE dumb > DEVICE /dev/cuaa0 > LOCKFILE /var/spool/lock > > ONBATTERYDELAY 10 > > BATTERYLEVEL 20 > MINUTES 5 > TIMEOUT 600 > Nope. Same thing. Well, first off, try setting UPSTYPE to "apcsmart" then just set UP

Re: troubles with apcupsd (basic setup)

2005-11-23 Thread Peter
--- Greg Maruszeczka <[EMAIL PROTECTED]> wrote: > Peter wrote: > > Hello. I have an APC BackUPS 650 and I want to have my FreeBSD 5.4 > system > > shutdown on power failure. I received a cable with the unit but there > are > > no identifying markings. When I run apcupsd it thinks there is a >

Re: troubles with apcupsd (basic setup)

2005-11-23 Thread Greg Maruszeczka
Peter wrote: > Hello. I have an APC BackUPS 650 and I want to have my FreeBSD 5.4 system > shutdown on power failure. I received a cable with the unit but there are > no identifying markings. When I run apcupsd it thinks there is a power > failure and proceeds to shut me down. Can anyone help?

troubles with apcupsd (basic setup)

2005-11-23 Thread Peter
Hello. I have an APC BackUPS 650 and I want to have my FreeBSD 5.4 system shutdown on power failure. I received a cable with the unit but there are no identifying markings. When I run apcupsd it thinks there is a power failure and proceeds to shut me down. Can anyone help? My config file: UPS