Reviewed-by: Bernd Porr
Ian Abbott wrote:
The `cmdtest` and `cmd` handlers for the AO subdevice
(`usbduxsigma_ao_cmdtest()` and `usbduxsigma_ao_cmd()`) support "scan"
timing of commands with all channels updated every "scan" period. There
is some disabled code to use "convert" timing in high s
The `cmdtest` and `cmd` handlers for the AO subdevice
(`usbduxsigma_ao_cmdtest()` and `usbduxsigma_ao_cmd()`) support "scan"
timing of commands with all channels updated every "scan" period. There
is some disabled code to use "convert" timing in high speed mode. That
would allow channels to be up