Thanks for the clue..it is a bug on the switch..I checked with an older
implementation of the switch and worked as expected..
-Original Message-
From: Ben Pfaff [mailto:b...@nicira.com]
Sent: Wednesday, May 08, 2013 12:23 PM
To: Nagi Reddy Jonnala
Cc: discuss@openvswitch.org
Subject: Re
On Wed, May 08, 2013 at 12:15:43PM -0700, Nagi Reddy Jonnala wrote:
> $ovs-ofctl --flow-format openflow10 dump-aggregate tcp:10.25.129.5 "
> in_port=1" -v
> 2013-05-08T19:13:08Z|1|poll_loop|DBG|wakeup due to [POLLOUT] on fd 5
> (10.20.99.23:34628<->10.25.129.5:6633) at lib/stream-fd.c:139
> 2
I use the below OVS version
ovs-ofctl --version
ovs-ofctl (Open vSwitch) 1.7.1
Compiled Jan 14 2013 16:02:07
OpenFlow versions 0x1:0x1
I observe the below behavior/issues. I don't see any meaningful PDU going out
to dump flow stats / aggregate stats.
$ovs-ofctl --flow-format openflow10 dump-a