On May 6, 2013, at 4:09 PM, Luiz Ozaki wrote:
> On 5/6/13 7:21 PM, Ben Pfaff wrote:
>> On Mon, May 06, 2013 at 05:41:53PM -0300, Luiz Ozaki wrote:
>>> Production works fine BUT at the LAB the IN_PORT that I'm passing is
>>> 3 and it's matching with the IN_PORT 174 from my OF rule.
>> The in_port
On 5/6/13 7:21 PM, Ben Pfaff wrote:
On Mon, May 06, 2013 at 05:41:53PM -0300, Luiz Ozaki wrote:
Production works fine BUT at the LAB the IN_PORT that I'm passing is
3 and it's matching with the IN_PORT 174 from my OF rule.
The in_port value in this form of ofproto/trace is a kernel datapath
por
On Mon, May 06, 2013 at 05:41:53PM -0300, Luiz Ozaki wrote:
> Production works fine BUT at the LAB the IN_PORT that I'm passing is
> 3 and it's matching with the IN_PORT 174 from my OF rule.
The in_port value in this form of ofproto/trace is a kernel datapath
port number, not an OpenFlow one. The
Hello,
I'm making some changes on my controller so I'm getting some DP flows
from production and passing into my new controller/OVS (Which is awesome
by the way).
*Production:*
ovs-appctl ofproto/trace xapi5
"in_port(3),eth(src=56:d0:ec:e5:24:96,dst=02:e0:52:2a:ef:24),eth_type(0x0800),ipv4(