Reading Section 5.10 (Action Set) of the OpenFlow 1.3 spec, it seems that
pop vlan
Action should have been executed before output.
On 6/25/14, 3:26 PM, "Ben Pfaff" wrote:
>On Wed, Jun 25, 2014 at 06:55:52PM +, Patil, Vishal wrote:
>> BTW I see similar issue with
>
Ben
BTW I see similar issue with
actions=output:3,strip_vlan
With actions specified in this order, the packet is directly sent to port 3
Without the vlan being stripped.
- Vishal
On 6/25/14, 2:38 PM, "Ben Pfaff" wrote:
>On Wed, Jun 25, 2014 at 03:56:15PM +, Patil, Visha
I have the following flow set on my OVS
in_port=2,dl_src=fa:16:3e:00:05:90
actions=set_field:102->vlan_vid,push_vlan:0x8100,goto_table:10
The problem is this flow does not set the vlan id on the packets as
expected. However if I modify the
Flow such that the ³push_vlan² is set before ³Set_field²,