Hi,
With the following are the platform specifications:
OVS version: 1.4.0
traffic type: MTU size UDP packets @7000packets per second, generating
50,000 flows by changing UDP src Ports.
OS: Fedora release 12, Linux 2.6.31.5-127.fc12.i686.PAE
CPU: Intel Core i3 @ 2100 GHz
Contr
Are you planning to solve this problem in near future or do you have any
suggestions to mitigate this problem?
On Thu, Apr 26, 2012 at 2:37 AM, Ben Pfaff wrote:
> On Wed, Apr 25, 2012 at 01:33:56PM -0700, Joji Mtt wrote:
> > I am trying to figure out if there would be a packet order issue with t
the patch has solved my problem. thanks a lot
On Wed, Apr 25, 2012 at 10:52 AM, junaid khalid <
junaid.kha...@seecs.nust.edu.pk> wrote:
> Thanks a lot. I will update you after testing it
>
>
> On Wed, Apr 25, 2012 at 10:45 AM, Ben Pfaff wrote:
>
>> On Wed, Apr 2
Thanks a lot. I will update you after testing it
On Wed, Apr 25, 2012 at 10:45 AM, Ben Pfaff wrote:
> On Wed, Apr 25, 2012 at 10:38:45AM +0500, junaid khalid wrote:
> > we are talking about the recv failed problem (system@br0: recv failed
> (No
> > buffer space available)).
&g
handle this rate easily.
On Wed, Apr 25, 2012 at 10:31 AM, Ben Pfaff wrote:
> On Wed, Apr 25, 2012 at 10:28:05AM +0500, junaid khalid wrote:
> > On Wed, Apr 25, 2012 at 10:14 AM, Ben Pfaff wrote:
> >
> > > On Wed, Apr 25, 2012 at 09:43:50AM +0500, junaid khalid wrote:
> &g
On Wed, Apr 25, 2012 at 10:14 AM, Ben Pfaff wrote:
> On Wed, Apr 25, 2012 at 09:43:50AM +0500, junaid khalid wrote:
> > On Tue, Apr 24, 2012 at 9:06 PM, Ben Pfaff wrote:
> >
> > > On Tue, Apr 24, 2012 at 07:02:37PM +0600, junaid khalid wrote:
> > > > Do y
On Tue, Apr 24, 2012 at 9:06 PM, Ben Pfaff wrote:
> On Tue, Apr 24, 2012 at 07:02:37PM +0600, junaid khalid wrote:
> > Do you mean the setup of flows in cached flow table in kernel module? We
> > are sending packets after setting up the flows. Therefore, this problem
> >
packets are passed from
the switch; received from one interface and sent out from the other
interface of NIC.
On Tue, Apr 24, 2012 at 2:55 AM, Ben Pfaff wrote:
> On Mon, Apr 23, 2012 at 03:54:09PM +0600, junaid khalid wrote:
> > 1) Apr 23 13:19:27|00019|dpif|WARN|system@br0: recv failed (
Just to add, we are not rate limiting the log messages.
On Mon, Apr 23, 2012 at 3:54 PM, junaid khalid <
junaid.kha...@seecs.nust.edu.pk> wrote:
> Hi,
>
> We are getting the following warnings while using OVS.
>
> 1) Apr 23 13:19:27|00019|dpif|WARN|system@br0: recv fail
nce or functionality of OVS? How
should we resolve this problem? Any suggestions or pointers are
highly appreciated.
thanks and regards,
Junaid Khalid
Apr 23 13:19:16|1|reconnect|INFO|unix:./var/run/openvswitch/db.sock:
connecting...
Apr 23 13:19:16|2|reconnect|INFO|unix:./var/run/openv
Hi
I was running OVS (ovs-1.1.2 in kernel mode, on a core i7 machine with 4GB
of RAM) under several Gbps of load. I noticed some unexpected behavior; OVS
would disconnect from Controller (NOX 0.9 zaku) under heavy load conditions
and re-establish the connection when the load was reduced (the behav
On Mon, Oct 31, 2011 at 11:07 AM, Ben Pfaff wrote:
> On Sat, Oct 29, 2011 at 01:36:33AM -0700, junaid khalid wrote:
> > I have an issue regarding the ARP packet. I am generating an arp request
> > from my controller with the source Mac address same as of my NIC. I
> didn'
But
when i use some other source mac address ,i recevie its reply on the
controller. Is it a possible BUG or is there something wrong with my
configuration
P.S. I am using openvswitch 1.2.2
--
Regards,
-junaid khalid
___
discuss mailing list
di
13 matches
Mail list logo