Hi Zoli,
On 01/07/14 20:52, Zoltan Kiss wrote:
This patch modifies the LACP selection logic by prefering a slaves with up and
running partners when looking for a lead.
That fixes the following scenario:
- bond has 2 ports, A and B, their other ends are in separate chassis with
MC-LAG sync
- t
Since the sys_id is different from the existing ones, when partner of A came
back, partner of A shouldn't be really added to lacp (which isn't possible) or
shouldn't be considered to be the "lead".
Thanks,
Anoob.
From: Zoltan Kiss
Sent: 01 July 2014 20:5
This patch modifies the LACP selection logic by prefering a slaves with up and
running partners when looking for a lead.
That fixes the following scenario:
- bond has 2 ports, A and B, their other ends are in separate chassis with
MC-LAG sync
- the partner of port A is restarted
- port B is still