Re: Bug#872556: libc0.1: clock() has wrong scaling factor on hurd

2017-08-22 Thread Samuel Thibault
Control: tags -1 + pending Hello, James Cowgill, on ven. 18 août 2017 14:32:05 +0100, wrote: > The clock() function on hurd has the wrong scaling factor. Ok, it seems the confusion is due to this (from times(2) manual): “Note that clock(3) also returns a value of type clock_t, but this value is

Re: clock(3) non-functional?

2017-08-22 Thread Samuel Thibault
Hello, Svante Signell, on mar. 01 juil. 2014 14:59:01 +0200, wrote: > On Tue, 2014-07-01 at 14:47 +0200, Samuel Thibault wrote: > > Svante Signell, le Tue 01 Jul 2014 14:40:44 +0200, a écrit : > > > > > > $ ./test > > > > > > start = 3870 > > > > > > end = 3910 > > > > > > cpu_time_used = 0.40