Dear Raphaël,
Thanks so much for your help!
The upstream bug report is at https://github.com/linrunner/TLP/issues/670.
Best,
Benedikt
Hi again,
I contacted the upstream developer and he'd like you to open an issue
there directly.
The project page is at https://github.com/linrunner/TLP
For starters he needs the output of :
$ tlp-stat --cdiff -s -b
Once you've done that, please reply here with the address of the issue
repo
Le 08/01/2023 à 14:18, Benedikt Ahrens a écrit :
Dear Raphaël,
Thanks a lot for your advice. The change you propose does not solve the
problem:
```
tpacpi-bat.BAT0.startThreshold = 0 [%]
tpacpi-bat.BAT0.stopThreshold = 100 [%]
t
Dear Raphaël,
Thanks a lot for your advice. The change you propose does not solve the
problem:
```
# tlp-stat -b
--- TLP 1.5.0
+++ Battery Care
Plugin: thinkpad
Supported features: charge thresholds, recalibration
Driver usage:
* natacpi (thinkpad_ac
Le 07/01/2023 à 17:07, Benedikt Ahrens a écrit :
What model of ThinkPad do you have ?
I have a T14 G3.
It's a fairly recent model (February 2022), I can't say if it's not
supported by thinkpad_acpi yet, but trying good old acpi_call may be
worth it. Bear in mind that I'm only the package ma
On 07/01/2023 16:21, Raphaël Halimi wrote:
What model of ThinkPad do you have ?
I have a T14 G3.
Maybe the natacpi driver doesn't work and you need another one.
I don't know how to switch to another driver. Would you be able to point
me to documentation on how to do that?
Thanks a lot!
Le 07/01/2023 à 14:04, Benedikt Ahrens a écrit :
Dear Raphaël,
Thanks a lot for your advice.
I have uncommented the corresponding lines in the configuration file
(which I am sending in attachment). However, the output of `tlp-stat -b`
still shows no change to the charge thresholds, even after
Dear Raphaël,
Thanks a lot for your advice.
I have uncommented the corresponding lines in the configuration file
(which I am sending in attachment). However, the output of `tlp-stat -b`
still shows no change to the charge thresholds, even after reboot:
```
# tlp-stat -b
--- TLP 1.5.0 -
Hi,
Sorry for the late answer, the e-mail from the BTS fell into my spam folder.
Usually, in configuration files, a hash symbol (#) indicates a comment,
and is ignored by the software.
It seems that you didn't un-comment the lines when modifying the charge
thresholds. Remove the # symbol in
Package: tlp
Version: 1.5.0-1
Severity: normal
X-Debbugs-Cc: benedikt.ahr...@gmx.net
Dear Maintainer,
TLP does not set the battery charge threshold configured in the TLP
configuration file.
Specifically, the configuration file (attached) aims to set the battery charge
thresholds to something lik
10 matches