Hi Don,
I reconfigured the Monitors network recently.
My environment is ceph 0.80.7; Openstack Icehouse ; nova, glance, cinder
using ceph RBD ; RHEL7.0 nodes.
The first thing to do is to check that your new network config will
allow communications between your MONs (I assume you have 3 mons),
Hello,
If I write 2 different objects, eg, "john" and "paul" respectively to
a same pool like "testpool" in the cluster, is the primary OSD
calculated by CRUSH for the 2 objects the same?
--
Den
___
ceph-users mailing list
ceph-users@lists.ceph.com
htt
Hi
I have installed 6 node ceph cluster and to my surprise when I ran rados
bench I saw that random write has more performance number then sequential
write. This is opposite to normal disk write. Can some body let me know if
I am missing any ceph Architecture point here ?
__
Hi Sumit
Do you have cache pool tiering activated ?
Some feed-back regarding your architecture ?
Thanks
Sent from my iPad
> On 1 févr. 2015, at 15:50, Sumit Gaur wrote:
>
> Hi
> I have installed 6 node ceph cluster and to my surprise when I ran rados
> bench I saw that random write has more
On 01/02/2015 14:47, Dennis Chen wrote:
> Hello,
>
> If I write 2 different objects, eg, "john" and "paul" respectively to
> a same pool like "testpool" in the cluster, is the primary OSD
> calculated by CRUSH for the 2 objects the same?
Hi,
CRUSH is likely to place john on an OSD and paul on
Hi All,
CEPHFS - Given a file name, how can one determine the exact location and
the name of the objects on OSDs.
So far I could understand that the objects data is stored in .../current
dir in OSDs, but what naming convention do they use?
Many thanks in advance
Thanks
Mudit
___
Hello,
In the past we've been able to manually create specific and arbitrary
OSD numbers. Using the procedure:
1. Add OSD.# to ceph.conf (replicate)
2. Make necessary dir in /var/lib/ceph/osd/ceph-#
3. Create OSD+Journal partitions and filesystems, then mount it
4. Init data dirs with: ceph-os
Hi Howard,
I assume it's an typo with 160 + 250 MB.
Ceph OSDs must be min. 10GB to get an weight of 0.01
Udo
On 31.01.2015 23:39, Howard Thomson wrote:
> Hi All,
>
> I am developing a custom disk storage backend for the Bacula backup
> system, and am in the process of setting up a trial Ceph syst
Hi
You can verify the exact mapping using the following command: ceph osd map
{poolname} {objectname}
Check page http://docs.ceph.com/docs/master/man/8/ceph for the ceph command.
Cheers
JC
While moving. Excuse unintended typos.
> On Feb 1, 2015, at 08:04, Loic Dachary wrote:
>
>
>
>> On
Hi Verma
All lauout questions are detailed here for CephFS.
http://docs.ceph.com/docs/master/cephfs/file-layouts/
Hope this is what you are looking for
Cheers
JC
While moving. Excuse unintended typos.
> On Feb 1, 2015, at 08:08, Mudit Verma wrote:
>
> Hi All,
>
> CEPHFS - Given a file na
It's inode number (in hex), then ".", then block number (in hex). You can get
the ino of a file with stat.
sage
On February 1, 2015 5:08:18 PM GMT+01:00, Mudit Verma
wrote:
>Hi All,
>
>CEPHFS - Given a file name, how can one determine the exact location
>and
>the name of the objects on OSDs.
Hi,
I'm currently trying to understand how to setup correctly a pool with erasure
code
https://ceph.com/docs/v0.80/dev/osd_internals/erasure_coding/developer_notes/
My cluster is 3 nodes with 6 osd for each node (18 osd total).
I want to be able to survive of 2 disk failures, but also a full
Hi folks,
I was running a ceph cluster with 33 OSDs. More recently, 33x6 new OSDs
hosted on 33 new servers were added, and I have finished balancing the data
and then marked the 33 old OSDs out.
As I have 6x as many OSDs, I am thinking of increasing pg_num of my largest
pool from 1k to at least 8
Hi Alexandre,
On 01/02/2015 18:15, Alexandre DERUMIER wrote:
> Hi,
>
> I'm currently trying to understand how to setup correctly a pool with erasure
> code
>
>
> https://ceph.com/docs/v0.80/dev/osd_internals/erasure_coding/developer_notes/
>
>
> My cluster is 3 nodes with 6 osd for each node
Hi Alexandre,
nice to meet you here ;-)
With 3 hosts only you can't survive an full node failure, because for
that you need
host >= k + m.
And k:1 m:2 don't make any sense.
I start with 5 hosts and use k:3, m:2. In this case two hdds can fail or
one host can be down for maintenance.
Udo
PS: yo
Hi,
I don't know the general calculation, but last week we split a pool with 20
million tiny objects from 512 to 1024 pgs, on a cluster with 80 OSDs. IIRC
around 7 million objects needed to move, and it took around 13 hours to
finish. The bottleneck in our case was objects per second (limited to
ar
In my case, each object is 8MB (glance default for storing images on rbd
backend.) RBD doesn't work extremely well when ceph is recovering - it is
common to see hundreds or a few thousands of blocked requests (>30s to
finish). This translates high IO wait inside of VMs, and many applications
don't
Hi Xu,
On 01.02.2015 21:39, Xu (Simon) Chen wrote:
> RBD doesn't work extremely well when ceph is recovering - it is common
> to see hundreds or a few thousands of blocked requests (>30s to
> finish). This translates high IO wait inside of VMs, and many
> applications don't deal with this well.
th
Hi,
When do you see thousands of slow requests during recovery... Does that
happen even with single OSD failures? You should be able to recover disks
without slow requests.
I always run with recovery op priority at the minimum 1. Tweaking the
number of max backfills did not change much during that
Dan,
I alway have noout set, so that single OSD failures won't trigger any
recovery immediately. When the OSD (or sometimes multiple OSDs on the same
server) comes back, I do see slow requests during backfilling, but probably
not thousands. When I added a brand new OSD into the cluster, for some
r
Hi,
On 1 Feb 2015 22:04, "Xu (Simon) Chen" wrote:
>
> Dan,
>
> I alway have noout set, so that single OSD failures won't trigger any
recovery immediately. When the OSD (or sometimes multiple OSDs on the same
server) comes back, I do see slow requests during backfilling, but probably
not thousands.
On Fri, Jan 30, 2015 at 10:09:32PM +0100, Udo Lembke wrote:
> Hi Bruce,
> you can also look on the mon, like
> ceph --admin-daemon /var/run/ceph/ceph-mon.b.asok config show | grep cache
rbd cache is a client setting, so you have to check this connecting to
the client admin socket. Its location is
Hi,
I’ve ACL with key/user on on 1 pool (client.condor rwx on pool
rbdpartigsanmdev01)
I would like to unprotect snapshot but I’ve below error :
rbd -n client.condor snap unprotect
rbdpartigsanmdev01/flaprdsvc01_lun003@sync#1.cloneref.2015-02-01.19:07:21
2015-02-01 22:53:00.903790 7f4d0036e760
Hi Florent,
Cache tiering , No .
** Our Architecture :
vdbench/FIO inside VM <--> RBD without cache <-> Ceph Cluster (6 OSDs + 3
Mons)
Thanks
sumit
[root@ceph-mon01 ~]# ceph -s
cluster 47b3b559-f93c-4259-a6fb-97b00d87c55a
health HEALTH_WARN clock skew detected on mon.ceph-mon02,
mon.c
Hello
I cant open rbd image after restart cluster. I user rbd image for KVM
virtual machine.
ceph version 0.87
uname -a
Linux ceph4 3.14.31-gentoo #1 SMP Fri Jan 30 22:24:11 YEKT 2015 x86_64
Intel(R) Xeon(R) CPU E5-2609 0 @ 2.40GHz GenuineIntel GNU/Linux
rbd info raid0n/homes
rbd: error opening
Ceph Version: 0.80.1
Server Number: 4
OSD Number: 6disks per server
All of the OSDs of one server can't start After this server restart, but other
3 servers can.
---
ceph -s:
[root@dn1 ~]# ceph -s
cluster 73ceed62-9a53-414b-95
Hi All,
What I saw after enabling RBD cache it is working as expected, means
sequential write has better MBps than random write. can somebody explain
this behaviour ? Is RBD cache setting must for ceph cluster to behave
normally ?
Thanks
sumit
On Mon, Feb 2, 2015 at 9:59 AM, Sumit Gaur wrote:
>
On Mon, Feb 2, 2015 at 12:04 AM, Loic Dachary wrote:
>
>
> On 01/02/2015 14:47, Dennis Chen wrote:
>> Hello,
>>
>> If I write 2 different objects, eg, "john" and "paul" respectively to
>> a same pool like "testpool" in the cluster, is the primary OSD
>> calculated by CRUSH for the 2 objects the sa
Thanks, I've have the answer with the 'ceph osd map ...' command
On Mon, Feb 2, 2015 at 12:50 AM, Jean-Charles Lopez wrote:
> Hi
>
> You can verify the exact mapping using the following command: ceph osd map
> {poolname} {objectname}
>
> Check page http://docs.ceph.com/docs/master/man/8/ceph for
BTW, you can make crush to always choose the same OSD as primary.
Regards,
Sudarshan
On Mon, Feb 2, 2015 at 9:26 AM, Dennis Chen
wrote:
> Thanks, I've have the answer with the 'ceph osd map ...' command
>
> On Mon, Feb 2, 2015 at 12:50 AM, Jean-Charles Lopez
> wrote:
> > Hi
> >
> > You can
Sumit,
I think random read/write will always outperform sequential read/write in Ceph
if we don’t have any kind of cache in front or you have proper striping enabled
in the image. The reason is the following.
1. If you are trying with the default image option, the object size is 4 MB and
the st
Hi Sudarshan,
Some hints for doing that ?
On Mon, Feb 2, 2015 at 1:03 PM, Sudarshan Pathak wrote:
> BTW, you can make crush to always choose the same OSD as primary.
>
> Regards,
> Sudarshan
>
> On Mon, Feb 2, 2015 at 9:26 AM, Dennis Chen
> wrote:
>>
>> Thanks, I've have the answer with the 'ce
Hi Sage,
Are there some methods to prevent the file from being stripped to
multiple objects? eg, the file will be mapped to only one object in
the client side with ceph FS interface...
On Mon, Feb 2, 2015 at 1:05 AM, Sage Weil wrote:
> It's inode number (in hex), then ".", then block number (in
Hello
I cant open rbd image after restart cluster. I user rbd image for KVM
virtual machine.
ceph version 0.87
uname -a
Linux ceph4 3.14.31-gentoo #1 SMP Fri Jan 30 22:24:11 YEKT 2015 x86_64
Intel(R) Xeon(R) CPU E5-2609 0 @ 2.40GHz GenuineIntel GNU/Linux
rbd info raid0n/homes
rbd: error opening
Hello Dennis,
You can create CRUSH rule to select one of osd as primary as:
rule ssd-primary {
ruleset 5
type replicated
min_size 5
max_size 10
step take ssd
step chooseleaf firstn 1 type host
step
35 matches