Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-30 Thread Nick Fisk
oy' > Cc: ceph-users@lists.ceph.com > Subject: Re: [ceph-users] Old vs New pool on same OSDs - Performance > Difference > > > -Original Message- > > From: Somnath Roy [mailto:somnath@sandisk.com] > > Sent: 29 June 2015 23:29 > > To: Nick Fisk &

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-30 Thread Nick Fisk
> -Original Message- > From: Somnath Roy [mailto:somnath@sandisk.com] > Sent: 29 June 2015 23:29 > To: Nick Fisk > Cc: ceph-users@lists.ceph.com > Subject: RE: [ceph-users] Old vs New pool on same OSDs - Performance > Difference > > Nick, > I think you

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-29 Thread Somnath Roy
] Sent: Monday, June 29, 2015 3:05 PM To: Somnath Roy Cc: ceph-users@lists.ceph.com Subject: RE: [ceph-users] Old vs New pool on same OSDs - Performance Difference Sorry, forgot to enable that. Here is another capture with it on and I think you are spot on as I can see a 100ms delay doing the g

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-29 Thread Nick Fisk
349 pg[0.128( v 26335'8141858 (26331'8138777,26335'8141858] local-les=26276 n=5243 ec=1 les/c 26276/26305 26264/26272/26272) [1,21,31] r=0 lpr=26272 crt=26335'8141855 lcod 26335'8141857 mlcod 26335'8141857 active+clean] publish_stats_to_osd 26349:8019961 2015-06-29 22:

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-29 Thread Somnath Roy
7;_snapset'... Thanks & Regards Somnath -Original Message- From: Nick Fisk [mailto:n...@fisk.me.uk] Sent: Monday, June 29, 2015 4:54 AM To: Somnath Roy Cc: ceph-users@lists.ceph.com Subject: RE: [ceph-users] Old vs New pool on same OSDs - Performance Difference Hi Somnath, Sorry for the

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-29 Thread Nick Fisk
335'1369662] local-les=26276 n=5050 ec=1 les/c 26276/26311 26264/26270/26270) [1,23,11] r=0 lpr=26270 crt=26335'1369659 lcod 26335'1369661 mlcod 26335'1369661 active+clean] log_op_stats osd_op(client.2808923.0:188 rb.0.1ba70.238e1f29.264a [read 720896~65536] 0.52c3

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-20 Thread Somnath Roy
sts.ceph.com > Subject: Re: [ceph-users] Old vs New pool on same OSDs - Performance > Difference > > Nick, > I think the only IO operation between 'reached_pg' and 'started' is > fetching the xttrs. Check the following. > > 1. Enable debug log 20 (

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-20 Thread Nick Fisk
this helps, > > Thanks & Regards > Somnath > > -Original Message- > From: Nick Fisk [mailto:n...@fisk.me.uk] > Sent: Saturday, June 20, 2015 8:10 AM > To: Somnath Roy > Cc: ceph-users@lists.ceph.com > Subject: RE: [ceph-users] Old vs New pool on same OSDs

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-20 Thread Somnath Roy
this helps, Thanks & Regards Somnath -Original Message- From: Nick Fisk [mailto:n...@fisk.me.uk] Sent: Saturday, June 20, 2015 8:10 AM To: Somnath Roy Cc: ceph-users@lists.ceph.com Subject: RE: [ceph-users] Old vs New pool on same OSDs - Performance Difference Sorry to dig up this old thre

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-20 Thread Nick Fisk
20 15:39:05.679615", "event": "done" } ] ] The main delay seems to happen between reached_pg and started, any idea what would be happening in this period? Nick > -Original Message- > Fr

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-05 Thread Somnath Roy
Old vs New pool on same OSDs - Performance Difference > -Original Message- > From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf > Of Somnath Roy > Sent: 04 June 2015 22:41 > To: Nick Fisk; 'Gregory Farnum' > Cc: ceph-users@lists.ceph.com > Subject:

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-05 Thread Nick Fisk
> -Original Message- > From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf Of > Somnath Roy > Sent: 04 June 2015 22:41 > To: Nick Fisk; 'Gregory Farnum' > Cc: ceph-users@lists.ceph.com > Subject: Re: [ceph-users] Old vs New pool on same

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-04 Thread Somnath Roy
, June 04, 2015 2:12 PM To: 'Gregory Farnum'; Somnath Roy Cc: ceph-users@lists.ceph.com Subject: RE: [ceph-users] Old vs New pool on same OSDs - Performance Difference > -Original Message- > From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf > Of Gregory

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-04 Thread Nick Fisk
> -Original Message- > From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf Of > Gregory Farnum > Sent: 04 June 2015 21:22 > To: Nick Fisk > Cc: ceph-users@lists.ceph.com > Subject: Re: [ceph-users] Old vs New pool on same OSDs - Performance > Diffe

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-04 Thread Gregory Farnum
On Thu, Jun 4, 2015 at 6:31 AM, Nick Fisk wrote: > > Hi All, > > I have 2 pools both on the same set of OSD’s, 1st is the default rbd pool > created at installation 3 months ago, the other has just recently been > created, to verify performance problems. > > As mentioned both pools are on the sa

Re: [ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-04 Thread Somnath Roy
ceph-users@lists.ceph.com Subject: [ceph-users] Old vs New pool on same OSDs - Performance Difference Hi All, I have 2 pools both on the same set of OSD's, 1st is the default rbd pool created at installation 3 months ago, the other has just recently been created, to verify performance prob

[ceph-users] Old vs New pool on same OSDs - Performance Difference

2015-06-04 Thread Nick Fisk
Hi All, I have 2 pools both on the same set of OSD's, 1st is the default rbd pool created at installation 3 months ago, the other has just recently been created, to verify performance problems. As mentioned both pools are on the same set of OSD's, same crush ruleset and RBD's on both are id