Re: [ceph-users] CephFs - Ceph-fuse Client Read Performance During Cache Tier Flushing

2015-04-27 Thread Mohamed Pakkeer
Hi all The issue is resolved after upgrading Ceph from Giant to Hammer(0.94.1) cheers K.Mohamed Pakkeer On Sun, Apr 26, 2015 at 11:28 AM, Mohamed Pakkeer wrote: > Hi > > I was doing some testing on erasure coded based CephFS cluster. cluster > is running with giant 0.87.1 release. > > > > Clu

[ceph-users] CephFs - Ceph-fuse Client Read Performance During Cache Tier Flushing

2015-04-25 Thread Mohamed Pakkeer
Hi I was doing some testing on erasure coded based CephFS cluster. cluster is running with giant 0.87.1 release. Cluster info 15 * 36 drives node(journal on same osd) 3 * 4 drives SSD cache node( Intel DC3500) 3 * MON/MDS EC 10 +3 10G Ethernet for private and cluster network We got app