Hello List,
i have 3 Node with size = 2 and min_size = 2 (i will change it to
size=3). Connected via 10GBit. IPerf shows about 8.8GBit/sec.
I just want to make sure everthing is okay until here. ( since i have
a rbd benchmark problem )
The Nodes have HDDs (spinning rust) and here is "ceph tell os
Hello,
is there a difference between those two benchmarks?
I mean, with rados i get the expected results, and rbd bench ist far
away from it.
I was not able to see any bottlenecks at all. It looked like with
rados bench the disk did a lot more work than with rbd bench. Any
ideas on this?
rados b
efault"
},
{
"op": "chooseleaf_firstn",
"num": 0,
"type": "host"
},
{
"op": "emit"
}
]
}
]
Thanks,
Mario
On Sun, D
Hello List,
i have size = 3 and min_size = 2 with 3 Nodes.
My OSDs:
ceph osd tree
ID CLASS WEIGHT TYPE NAME STATUS REWEIGHT PRI-AFF
-1 60.17775 root default
-2 20.21155 host ceph01
0 hdd 1.71089 osd.0 up 1.0 1.0
8 hdd 1.71660 osd.8
MiB/sec 40 IOPS
Thanks,
Mario
On Tue, Dec 24, 2019 at 1:46 AM Christian Balzer wrote:
>
>
> Hello,
>
> On Mon, 23 Dec 2019 22:14:15 +0100 Ml Ml wrote:
>
> > Hohoho Merry Christmas and Hello,
> >
> > i set up a "poor man´s" ceph cluster with 3 No
Hohoho Merry Christmas and Hello,
i set up a "poor man´s" ceph cluster with 3 Nodes, one switch and
normal standard HDDs.
My problem; with rbd benchmark i get 190MB/sec write, but only
45MB/sec read speed.
Here is the Setup: https://i.ibb.co/QdYkBYG/ceph.jpg
I plan to implement a separate switc