Do you have statistics on the size of the OSDMaps or count of them
which were being maintained by the OSDs? I'm not sure why having noout
set would change that if all the nodes were alive, but that's my bet.
-Greg
On Thu, Oct 3, 2019 at 7:04 AM Vladimir Brik
wrote:
>
> And, just as unexpectedly,
Hmm, that assert means the monitor tried to grab an OSDMap it had on
disk but it didn't work. (In particular, a "pinned" full map which we
kept around after trimming the others to save on disk space.)
That *could* be a bug where we didn't have the pinned map and should
have (or incorrectly thought
The 4M throughput numbers you see now ( 150 MB/s read, 60 MB/s write)
are probably limited by your 1G network, and can probably go higher if
you increase it ( 10G or use active bonds).
In real life, the applications and wokloads determine the block size, io
depths, whether it is sequential o
Thank you guys,
I changed FIO parameters and it looks far better now - reading about
150MB/s, writing over 60MB/s
Now, the question is, what could I change in my setup to make it this
fast - the RBD is used as LVM PV for a VG shared between Xen
hypervisors, this is the PV:
--- Physical v
Swami;
For 12.2.11 (Luminous), the previously linked document would be:
https://docs.ceph.com/docs/luminous/radosgw/multisite/#migrating-a-single-site-system-to-multi-site
Thank you,
Dominic L. Hilsbos, MBA
Director – Information Technology
Perform Air International Inc.
dhils...@performair.co
hi all,
maybe to clarify a bit, e.g.
https://indico.cern.ch/event/755842/contributions/3243386/attachments/1784159/2904041/2019-jcollet-openlab.pdf
clearly shows that the db+wal disks are not saturated,
but we are wondering what is really needed/acceptable wrt throughput and
latency (eg is a 6gbps
WAL/DB isn't "read intensive". It's more "write intensive" :) use server
SSDs with capacitors to get adequate write performance.
Hi all,
We are thinking about putting our wal/db of hdds/ on ssds. If we would
put the wal&db of 4 HDDS on 1 SSD as recommended, what type of SSD would
suffice?
We
The tests are measuring differing things, and fio test result of 1.5
MB/s is not bad.
The rados write bench uses by default 4M block size and does 16 threads
and is random in nature, you can change the block size and thread count.
The dd command uses by default 512 block size and and 1 thread
Hi,
your RBD bench and RADOS bench use by default 4MB IO request size while your
FIO is configured for 4KB IO request size.
If you want to compare apple 2 apple (bandwidth) you need to change the FIO IO
request size to 4194304. Plus, you tested a sequential workload with RADOS
bench but random
Hello,
I tried to use FIO on RBD device I just created and writing is really
terrible (around 1.5MB/s)
[root@ceph3 tmp]# fio test.fio
rbd_iodepth32: (g=0): rw=randwrite, bs=(R) 4096B-4096B, (W) 4096B-4096B,
(T) 4096B-4096B, ioengine=rbd, iodepth=32
fio-3.7
Starting 1 process
Jobs: 1 (f=1): [
Hi,
>>dd if=/dev/zero of=/dev/rbd0 writes at 5MB/s -
you are testing with a single thread/iodepth=1 sequentially here.
Then only 1 disk at time, and you have network latency too.
rados bench is doing 16 concurrent write.
Try to test with fio for example, with bigger iodepth, small block/big b
Hello,
If this is too long for you, TL;DR; section on the bottom
I created a CEPH cluster made of 3 SuperMicro servers, each with 2 OSD
(WD RED spinning drives) and I would like to optimize the performance of
RBD, which I believe is blocked by some wrong CEPH configuration,
because from my ob
Hi all,
We are thinking about putting our wal/db of hdds/ on ssds. If we would
put the wal&db of 4 HDDS on 1 SSD as recommended, what type of SSD would
suffice?
We were thinking of using SATA Read Intensive 6Gbps 1DWPD SSDs.
Does someone has some experience with this configuration? Would we n
Maybe this will help you:
https://docs.ceph.com/docs/master/radosgw/multisite/#migrating-a-single-site-system-to-multi-site
___
Clyso GmbH
Am 03.10.2019 um 13:32 schrieb M Ranga Swami Reddy:
Thank you. Do we have a quick document to do this migration?
Thanks
That would accomplish what you are looking for, yes.
Keep in mind that with norebalance that won't stop NEW data from landing there.
It will only keep old data from migrating in. This shouldn't pose too much of
an issue for most use cases.
--
Paul Mezzanini
Sr Systems Administrator / Engineer
Hi,our mon is acting up all of a sudden and dying in crash loop with the
following:
2019-10-04 14:00:24.339583 lease_expire=0.00 has v0 lc 4549352
-3> 2019-10-04 14:00:24.335 7f6e5d461700 5
mon.km-fsn-1-dc4-m1-797678@0(leader).paxos(paxos active c 4548623..4549352)
is_readable = 1 - no
>
>Try something like the following on each OSD that holds a copy of
>rbd_data.1f114174b0dc51.0974 and see what output you get.
>Note that you can drop the bluestore flag if they are not bluestore
>osds and you will need the osd stopped at the time (set noout). Also
>note, snapids
17 matches