Re: [ccp4bb] Error ARP/wARP MODE_WILSON

2009-03-14 Thread Victor Lamzin
Dear Kristof, This is a bug we are aware of. It will go as of the next release but for the moment the easiest is if we send you a fixed executable. What is your computer platform (please type 'uname' and let me know the output) ? With best regards, Victor Kristof Van Hecke wrote: Dear all,

Re: [ccp4bb] Error ARP/wARP MODE_WILSON

2009-03-14 Thread Anastassis Perrakis
Dear Kristof, There is a button to disable the Wilson Check, under 'ARP/wARP flow parameters'. Having 100% solvent though, to me looks very suspicious; very likely your file was misread by ARP/wARP, and the job will go wrong later. I admit I have never before added waters to DNA only and

[ccp4bb] Error ARP/wARP MODE_WILSON

2009-03-14 Thread Kristof Van Hecke
Dear all, When refining a DNA-structure (poor data, resolution 2.5) and using ARP/wARP Solvent 7.0.1. for water divining with CCP4 6.1.1 and GUI 2.0.4, I get the following error: QUITTING ... ARP/wARP module stopped with an error message: ARP_WARP_MODE_WILSON When checking the "warp_wilson_lo