Hi there
AMPLE works very well for coiled-coil structures, irrespective of
parallel/anti-parallel etc
http://journals.iucr.org/m/issues/2015/02/00/lz5005/
Resolution permitting, SHELXE tracing and phase modification, built into
the AMPLE pipeline, gives statistics that differentiate very cle
Hi ???,
Coiled coil structures can be very tricky with MR, so your solution may not be
correct. You could try to split your search model and run MR with the separate
coils. If you have high enough resolution (> ~2.3 Å?) and your MR solution is
basically correct, you may be able to solve your pr