Hi Cat,
If your pseudo-centering actually leads to significant change in your
cumulative intensity distribution, you might have a convincing explanation as
to why the R-values would remain on the high side. I had a pseudo-body centered
case a long time ago (https://doi.org/10.1107/s09074449
Hi Bashir,
It does look like you have translational pseudo-symmetry. If the translation
vector happens to be body-centering, it could affect your intensity statistics
so that the R-values would never go down as half of your reflections follow the
distribution for centric reflections. I had thi
Dear Manfred,
In addition to personal preference I think there are some philosophical
differences in what the model actually means. I would argue that what we see in
the density is stronger evidence of the chemical identity than what we believe
we have used as a starting material. After all we
Dear Colleagues,
I would like to bring to your attention a job opening at the Data Management
and Software Centre fo the European Spallation Source in Copenhagen, Denmark.
In this role your main responsibility will be the design and development of a
data processing pipeline optimized for
either myself or Prof. Ryde
(ulf.r...@teokem.lu.se<mailto:ulf.r...@teokem.lu.se>) for questions.
Best regards,
Esko
_
Esko Oksanen, PhD
Instrument Scientist - Neutron Macromolecular Crystallography
European Spallation Source ERIC
P.O Box 176, SE-221 00 Lund, Sweden
Vi
-file) should correspond
to the third column of your pdb-file, so that coot know what hydrogen that
should be. The only difference in your pdb-file compared to an X-ray structure
with hydrogens is the element symbol in the last column.
HTH,
Esko
_
Esko Oksanen, PhD
rmation about
the recruitment process, please contact Linda Sima, linda.sima[at]esss.se
(unavailable 2-25 August).
We look forward to receiving your application.
_____
Esko Oksanen, PhD
Instrument Scientist - Neutron Macromolecular Crystallography
European Spallation Source ESS AB
P.O
distribution; if it looks normal I don't think
the separate scaling will help you.
HTH,
Esko
_____
Esko Oksanen, PhD
Instrument Scientist - Neutron Macromolecular Crystallography
European Spallation Source ESS AB
P.O Box 176, SE-221 00 Lund, Sweden
Visiting address: Tunavägen 24,
Dear Acoot,
There is a paper by Monika Budayova-Spano
(http://scripts.iucr.org/cgi-bin/paper?fw5105) on using temperature as a
crystallisation variable that also has a number of useful references.
HTH,
Esko
_
Esko Oksanen, PhD
Instrument Scientist - Neutron
d any more.
HTH,
Esko
_____
Esko Oksanen, PhD
Instrument Scientist - Neutron Macromolecular Crystallography
European Spallation Source ESS AB
P.O Box 176, SE-221 00 Lund, Sweden
Visiting address: Tunavägen 24, Lund
Switchboard: +46 46 888 00 00
Phone: +46 46 888 30 36
Mobile:
and reflections
with h+k=2n. Which software could do this job? A brief tutorial is
appreciated.
Yu
--
Yu Zhang
HHMI associate
Waksman Institute, Rutgers University
190 Frelinghuysen Rd.
Piscataway, NJ, 08904
Esko Oksanen, PhD
Post-doctoral Fellow (EMBO)
Groupe Synchrotron, Institut de
Seema,
The problem actually originates from the scaling of the data that
assumes a monomodal distritbution of the intensities. This is not the
case with pseudotranslation and there are two sets of reflections: the
weak, pseudo-absent reflections and the strong reflections. The
scaling
Mike,
You could try rigid body refinement against the weak reflections to
get the position of the molecules right and then normal restrained
refinement against the strong reflections. I had a case like this some
years ago and that helped...
Esko
On 17.10.2010, at 6.48, Mike John wr
686F 78FD 6669 67BA 8D5D
Esko Oksanen, M.Sc., researcher
Macromolecular Structures Group
Research Program in Structural Biology and Biophysics
Institute of Biotechnology, University of Helsinki
Viikinkaari 1 P.O. Box 65
FIN-00014 Helsinki
FINLAND
tel. +358-9-19158953 fax +358-9-19159940
mob
Would it be too much to ask that the person sending the summary email
would also put that (or equivalent information) in the wiki?
Esko
Quoting Kay Diederichs <[EMAIL PROTECTED]>:
> Andreas Förster schrieb:
> > Hey Kay,
> >
> > I'm not even sure I see a problem with reposting. All ccp4 p
e and machining...
Esko
Esko Oksanen, M.Sc.
European Molecular Biology Laboratory, Grenoble Outstation
6 rue Jules Horowitz
BP 181
38042 Grenoble Cedex 9
FRANCE
tel. +33-4-76207633
mob. +33-6-67416110
Skype ejoksane
[EMAIL PROTECTED]
Quoting Harry Powell <[EMAIL PROTECTED]>:
> Hi
>
>
Francesco,
I recently had the same problem and I had to convert the ccp4 map to xplor
format first (with mapman) and then to situs format with map2map. A bit
annoying but it worked.
HTH,
Esko
Esko Oksanen, M.Sc.
European Molecular Biology Laboratory, Grenoble Outstation
6 rue Jules
ainst
the even (strong) reflections. In the presence of significant pseudo-
symmetry, the structure is probably never going to refine very well,
at least in terms of R-value, because it is no longer a very good
indicator of structure correctness...
HTH,
Esko