drop.
Hopefully your crystals will survive the transfer (test before).
Cheers,
Mario Sanches
On Wed, Jul 2, 2014 at 1:17 PM, Meisam Nosrati
wrote:
> Dear CCP4ers
>
> I need to transfer some crystals mainly in sitting drops to the site of
> data collection without freezing them.
>
>
> Faisal
> School of Life Sciences
> JNU
>
--
Mario Sanches
http://ca.linkedin.com/in/mariosanches
lobs shown in the structure models?
>
> Attached please find the images of the two blobs. Any clue what it is?
>
> Thank you for your comments and advices
>
> Uma
>
>
>
--
Mario Sanches
http://ca.linkedin.com/in/mariosanches
Hi Jacob,
I used Moleman to do that once (http://xray.bmc.uu.se/usf/moleman2_man.html
)
The Distance LIst command is probably what you are looking for.
Mario Sanches
On Mon, Nov 28, 2011 at 5:22 PM, Jacob Keller <
j-kell...@fsm.northwestern.edu> wrote:
> Dear Crystallographer
validation.
Good luck,
Mario Sanches
2011/9/30 Xiaopeng Hu
> Dear all,
>
> I just notified that there is a big difference between the Ramachandran
> plot analysis results produced by Coot and Morprobity (or Phenix). For the
> structure I am working now, Phenix(Morprobity) gives o
Testing for cracks in the column is quite easy. Take whichever standard you
happen to have (lisozyme, GST, etc) and do a run. If it comes out in a
single peak the problem is with your prep. If it comes out throughout the
run the problem is with your column.
Mario Sanches
On Sun, Aug 28, 2011 at
ist Training Program
> cel: 773.608.9185
> email: j-kell...@northwestern.edu
> ***
>
--
Mario Sanches
Postdoctoral Fellow
Samuel Lunenfeld Research Institute
Mount Sinai Hospital
600 University Ave
Toronto - Ontario
Canada
M5G 1X5
http://ca.linkedin.com/in/mariosanches
are many good references out there that deal
with production, purification and crystallization or RNA.
Good luck,
Mario Sanches
On Sun, Mar 13, 2011 at 4:39 AM, Michael Thompson wrote:
> Hello All,
>
> I am looking for some advice from some experienced RNA crystallographers. I
> woul
put mtz as the
input for coot. The Refmac mtz will have the map coefficient columns on it.
Good luck,
Mario Sanches
2011/3/7 王瑞
> I have an ambiguous question that can't decide where it belongs . In fact,
> I was going to refine my data after molecular replacement, but coot can't
Hi Sadaf,
You may want to try to play with the occupancy. I have had a case before
where the disulfide bond had double occupancy. In my case it was obvious
because I could see the other density, but sometimes you can just see a
major one due to disorder.
I hope that helps,
Mario Sanches
On Sun
D<http://www.ncbi.nlm.nih.gov/pubmed?term=%22Bordo%20D%22%5BAuthor%5D>
.
Mario Sanches
On Wed, Feb 16, 2011 at 3:48 PM, Filip Van Petegem <
filip.vanpete...@gmail.com> wrote:
> Hello all,
>
> Some crystal structures seem to contain a very low number of water
> molecules given their resolut
ive gel analysis (or other assays using purified protein) but
> protein complex crystal structure was solved.
>
>
>
> Thanks
>
> Happy Thanksgiving
>
> Yogi
>
>
>
>
>
--
Mario Sanches
Postdoctoral Fellow
Samuel Lunenfeld Research Institute
Mount Sinai Hospital
600 University Ave
Toronto - Ontario
Canada
M5G 1X5
http://ca.linkedin.com/in/mariosanches
figured in /etc/bash.bashrc so that they will be visible
everywhere for all users, so I think that was not the issue here.
Thank you again for the quick reply,
Mario Sanches
Gerrit Langer wrote:
Dear Mario,
it seems that inside the install script the path variable is not set
and therefore the
Dear all,
I am trying to install arp/warp and I am stuck with the following error:
--
Checking refmac5 installation - refmac5: Command not found.
*** ERROR ***
Cannot execute refmac5
*
Same thing to me. I was able to assign a PEG molecule to a similar density.
Mario Sanches
Jiamu Du wrote:
Oh..
Thank you. I will try to fit it with a piece of PEG.
Best wishes.
On Tue, Feb 26, 2008 at 10:38 PM, <[EMAIL PROTECTED]
<mailto:[EMAIL PROTECTED]>> wrote:
cold seals? I would appreciate if people
could tell me which seal they use, and at which temperature.
Thank you all in advance,
Mario Sanches
##
Those are the answers that I received:
We did extensive testing for this using caps, mat caps, tape, adhesive foil,
heat seal plastic
all in advance,
--
Mario Sanches
Laboratório Nacional de Luz Síncrotron
Cristalografia e Espectroscopia de Biomoléculas
Tel: +55 19 3512 1275
is, E., Dierks, K., Moreno, A., Dieckmann, W.M., and Chayen, N.E.
(2002) Separating nucleation and growth in protein crystallization using
dynamic light scattering, Acta Cryst. Sect. D, 58, 1597-1600.
HTH,
Mario Sanches
Jobichen Chacko wrote:
Hai All,
Sorry for the non Ccp4 question.
I got
18 matches
Mail list logo