Hi,
> What if instead of images we just collected a list of x-y coordinates of
> photon hits vs time?
This is how the Tristan detector works, it is based on timepix3 chips and the
data is a read as time stamped x-y co-ordinates + counts and then diffraction
images are reconstructed from this
Hello,
> What if instead of images we just collected a list of x-y coordinates of
> photon hits vs time?
This already exists, but for electrons:
https://doi.org/10.1107/S205225252000929X
This is the technology in Falcon4 detectors. The advantage is that it allows
you to decide how to slice
A few follow-up questions I got out-of-band:
how did you get to the 1:1 relationship between Bijvoet ratio and dose?
I got this from fitting a straight line to Table 1 of Banu's 2004 paper:
10.1107/S0907444904007917
Is this a rough estimate based on a singular result? Of course it is!
This
Dear all,
After half an year from the original Shivani's message, I am having the same
problem. Please has anybody successfully deposited data there recently or has
any idea how to reach the admins?
Cheers,
Martin
On 14/11/2023 00:16, Shivani Sharma wrote:
I deposited some raw data on the prot
Dear All
Thank you for the detailed response. I will implement the suggested fixes and
report back on a later date.
Kind regards,
Otsile
-Original Message-
From: CCP4 bulletin board On Behalf Of Bernhard Lohkamp
Sent: Wednesday, May 15, 2024 9:11 PM
To: CCP4BB@JISCMAIL.AC.UK
Subject: Re