Hi Diana,
At the risk of thread-jacking Ed’s question, yes, PHENIX handles this
seamlessly for us as well. However, REFMAC5 doesn’t like this scenario,
with or without alt. confs. or insertion codes. There are some models
where I’d really like to use REFMAC5 for refining these mixed species
model
The scenario I presented earlier works like a charm in refinement with the
Phenix program suite. For example, I have used it for both mixed populations of
ligands (e.g., AAMP and BADP) as well as phosphorylation (ASER and BSEP).
Diana
**
Diana R.
I agree. We have encountered refinement problems similar to those Ed
describes for models with mixtures of modified cysteine species, which is
a fairly common occurrence.
Best regards,
Mark
Mark A. Wilson
Associate Professor
Department of Biochemistry/Redox Biology Center
University of Nebraska
N1
Herman,
thanks - however, it seems like I have poorly worded my question. I do
know how to generate alternate conformers, what the PDB ATOM record format
is etc. The point was that when I have alternate conformers that carry the
same residue ID but different residue types, Refmac exits with the
The situation might not be so rare, if you consider 50% Lys and
50% Acetyl-Lys or other post-translational modifications.
Gottfried
On Wednesday, 06-02-2019 at 18:05 Diana Tomchick wrote:
If you have the odd case where one residue (of the same number in the
polypeptide chain) is a Leu and the
If you have the odd case where one residue (of the same number in the
polypeptide chain) is a Leu and the alternative residue is a Phe, then it would
be ALEU and BPHE, both residues would have the same residue number, and reset
the occupancies to fractions that sum to 1.0.
Diana
**
Structural Biology and Drug Development at the University of Oslo
[cid:45310D88-A655-46CE-828B-07D61B8B9026]
2 Postdoctoral Fellowships
Inhibitor discovery targeting the Helicobacter pylori pH acclimation system (a
pH-gated urea channel and a cytoplasmic urease)1
1Strugatsky et al. “Structure
Dear CCP4bb readers,
we are in the process of decommissioning our in-house X-ray source and would
like to offer it to the community:
Bruker MicroStar X-ray generator (non-functional, i.e. for repair or
replacement parts)
2 Helios Mx Cu X-Ray optics for Microstar
Mardtb Imaging Plate Detector
I
All the videos from the CCP4 Study Weekend 2019 are now available on the CCP4
YouTube channel.
Only the videos where the speakers have expressly given permission for them to
be uploaded are there.
Regards
Karen McIntyre
Science & Technology Facilties Council
Scientific Computing Department –
Dear CCP4 community,
The Protein Production and Structure Core Facility has a new open position for
a technical staff (CDI, 80-100%, location EPFL Lausanne Switzerland).
The main duties will be to advise, assist and follow-up X-ray crystallisation
projects for various users; as well as to produ
10 matches
Mail list logo